Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel
Journal cover image

High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla.

Publication ,  Journal Article
Thulborn, KR; Chang, SY; Shen, GX; Voyvodic, JT
Published in: NMR Biomed
1997

Known specialized properties of the human visual cortex have been used to investigate the role of spatial resolution on fMRI using blood oxygenation level dependent (BOLD) echo-planar MRI at 3.0 tesla. The magnitude of BOLD signal changes has been examined at low (3.1 x 3.1 x 3.0 mm3) and high (0.8 x 1.6 x 3.0 mm3) resolution using both gradient-echo and spin-echo EPI. Paradigms were designed to activate primary visual cortex (V1/V2) and more specialized areas associated with detection of color (V4) and motion (V5). Sensitivity of activation maps increased at higher resolution despite the decreased total signal intensity at the smaller voxel size, presumably from reduced partial volume averaging. The greater microvascular selectivity of high-resolution spin-echo imaging enabled distinct activation patterns sensitive to motion to be detected in V1/V2 that were not apparent with gradient-echo imaging. The spatial resolution at 3.0 tesla was constrained by the size of physiological head motion relative to the voxel dimensions rather than SNR or the hemodynamic response of BOLD contrast. The higher spatial resolution at 3.0 tesla with more selective spin-echo EPI can further refine functional mapping within the cerebral cortex.

Duke Scholars

Published In

NMR Biomed

DOI

ISSN

0952-3480

Publication Date

1997

Volume

10

Issue

4-5

Start / End Page

183 / 190

Location

England

Related Subject Headings

  • Visual Cortex
  • Space Perception
  • Quality Control
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Motion Perception
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Echo-Planar Imaging
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Thulborn, K. R., Chang, S. Y., Shen, G. X., & Voyvodic, J. T. (1997). High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla. NMR Biomed, 10(4–5), 183–190. https://doi.org/10.1002/(sici)1099-1492(199706/08)10:4/5<183::aid-nbm469>3.0.co;2-w
Thulborn, K. R., S. Y. Chang, G. X. Shen, and J. T. Voyvodic. “High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla.NMR Biomed 10, no. 4–5 (1997): 183–90. https://doi.org/10.1002/(sici)1099-1492(199706/08)10:4/5<183::aid-nbm469>3.0.co;2-w.
Thulborn KR, Chang SY, Shen GX, Voyvodic JT. High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla. NMR Biomed. 1997;10(4–5):183–90.
Thulborn, K. R., et al. “High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla.NMR Biomed, vol. 10, no. 4–5, 1997, pp. 183–90. Pubmed, doi:10.1002/(sici)1099-1492(199706/08)10:4/5<183::aid-nbm469>3.0.co;2-w.
Thulborn KR, Chang SY, Shen GX, Voyvodic JT. High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla. NMR Biomed. 1997;10(4–5):183–190.
Journal cover image

Published In

NMR Biomed

DOI

ISSN

0952-3480

Publication Date

1997

Volume

10

Issue

4-5

Start / End Page

183 / 190

Location

England

Related Subject Headings

  • Visual Cortex
  • Space Perception
  • Quality Control
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Motion Perception
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Echo-Planar Imaging