Thermal safety of vibro-acoustography using a confocal transducer.

Publication ,  Journal Article
Chen, S; Aquino, W; Alizad, A; Urban, MW; Kinnick, R; Greenleaf, JF; Fatemi, M
Published in: Ultrasound in medicine & biology
February 2010

Vibro-acoustography (VA) is an imaging method that forms a two-dimensional (2-D) image by moving two cofocused ultrasound beams with slightly different frequencies over the object in a C-scan format and recording acoustic emission from the focal region at the difference frequency. This article studies tissue heating due to a VA scan using a concentric confocal transducer. The three-dimensional (3-D) ultrasound intensity field calculated by Field II is used with the bio-heat equation to estimate tissue heating due to ultrasound absorption. Results calculated with thermal conduction and with blood perfusion, with conduction and without perfusion and without conduction and without perfusion are compared. Maximum heating due to ultrasound absorption occurs in the transducer's near-field and maximum temperature rise in soft tissue during a single VA scan is below 0.05 degrees C for all three attenuation coefficients evaluated: 0.3, 0.5 and 0.7 dB/cm/MHz. Transducer self-heating during a single VA scan measured by a thermocouple is less than 0.27 degrees C.

Duke Scholars

Published In

Ultrasound in medicine & biology

DOI

EISSN

1879-291X

ISSN

0301-5629

Publication Date

February 2010

Volume

36

Issue

2

Start / End Page

343 / 349

Related Subject Headings

  • Ultrasonics
  • Transducers
  • Thermography
  • Safety
  • Humans
  • Elasticity Imaging Techniques
  • Acoustics
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chen, S., Aquino, W., Alizad, A., Urban, M. W., Kinnick, R., Greenleaf, J. F., & Fatemi, M. (2010). Thermal safety of vibro-acoustography using a confocal transducer. Ultrasound in Medicine & Biology, 36(2), 343–349. https://doi.org/10.1016/j.ultrasmedbio.2009.10.003
Chen, Shigao, Wilkins Aquino, Azra Alizad, Matthew W. Urban, Randall Kinnick, James F. Greenleaf, and Mostafa Fatemi. “Thermal safety of vibro-acoustography using a confocal transducer.Ultrasound in Medicine & Biology 36, no. 2 (February 2010): 343–49. https://doi.org/10.1016/j.ultrasmedbio.2009.10.003.
Chen S, Aquino W, Alizad A, Urban MW, Kinnick R, Greenleaf JF, et al. Thermal safety of vibro-acoustography using a confocal transducer. Ultrasound in medicine & biology. 2010 Feb;36(2):343–9.
Chen, Shigao, et al. “Thermal safety of vibro-acoustography using a confocal transducer.Ultrasound in Medicine & Biology, vol. 36, no. 2, Feb. 2010, pp. 343–49. Epmc, doi:10.1016/j.ultrasmedbio.2009.10.003.
Chen S, Aquino W, Alizad A, Urban MW, Kinnick R, Greenleaf JF, Fatemi M. Thermal safety of vibro-acoustography using a confocal transducer. Ultrasound in medicine & biology. 2010 Feb;36(2):343–349.
Journal cover image

Published In

Ultrasound in medicine & biology

DOI

EISSN

1879-291X

ISSN

0301-5629

Publication Date

February 2010

Volume

36

Issue

2

Start / End Page

343 / 349

Related Subject Headings

  • Ultrasonics
  • Transducers
  • Thermography
  • Safety
  • Humans
  • Elasticity Imaging Techniques
  • Acoustics
  • 3202 Clinical sciences
  • 1103 Clinical Sciences