Skip to main content
Journal cover image

Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction.

Publication ,  Journal Article
Brau, ACS; Hedlund, LW; Johnson, GA
Published in: J Magn Reson Imaging
July 2004

PURPOSE: To tailor a cardiac magnetic resonance (MR) microscopy technique for the rat that combines improvements in pulse sequence design and physiologic control to acquire high-resolution images of cardiac structure and function. MATERIALS AND METHODS: Projection reconstruction (PR) was compared to conventional Cartesian techniques in point-spread function simulations and experimental studies to evaluate its artifact sensitivity. Female Sprague-Dawley rats were imaged at 2.0 T using PR with direct encoding of the free induction decay. Specialized physiologic support and monitoring equipment ensured consistency of biological motion and permitted synchronization of imaging with the cardiac and respiratory cycles. RESULTS: The reduced artifact sensitivity of PR offered improved delineation of cardiac and pulmonary structures. Ventilatory synchronization further increased the signal-to-noise ratio by reducing inter-view variability. High-quality short-axis and long-axis cine images of the rat heart were acquired with 10-msec temporal resolution and microscopic spatial resolution down to 175 microm x 175 microm x 1 mm. CONCLUSION: Integrating careful biological control with an optimized pulse sequence significantly limits both the source and impact of image artifacts. This work represents a novel integration of techniques designed to support measurement of cardiac morphology and function in rodent models of cardiovascular disease.

Duke Scholars

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

July 2004

Volume

20

Issue

1

Start / End Page

31 / 38

Location

United States

Related Subject Headings

  • Respiration
  • Rats, Sprague-Dawley
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Myocardial Contraction
  • Microscopy
  • Magnetic Resonance Imaging, Cine
  • Image Processing, Computer-Assisted
  • Female
  • Artifacts
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Brau, A. C. S., Hedlund, L. W., & Johnson, G. A. (2004). Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction. J Magn Reson Imaging, 20(1), 31–38. https://doi.org/10.1002/jmri.20089
Brau, Anja C. S., Laurence W. Hedlund, and G Allan Johnson. “Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction.J Magn Reson Imaging 20, no. 1 (July 2004): 31–38. https://doi.org/10.1002/jmri.20089.
Brau ACS, Hedlund LW, Johnson GA. Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction. J Magn Reson Imaging. 2004 Jul;20(1):31–8.
Brau, Anja C. S., et al. “Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction.J Magn Reson Imaging, vol. 20, no. 1, July 2004, pp. 31–38. Pubmed, doi:10.1002/jmri.20089.
Brau ACS, Hedlund LW, Johnson GA. Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction. J Magn Reson Imaging. 2004 Jul;20(1):31–38.
Journal cover image

Published In

J Magn Reson Imaging

DOI

ISSN

1053-1807

Publication Date

July 2004

Volume

20

Issue

1

Start / End Page

31 / 38

Location

United States

Related Subject Headings

  • Respiration
  • Rats, Sprague-Dawley
  • Rats
  • Nuclear Medicine & Medical Imaging
  • Myocardial Contraction
  • Microscopy
  • Magnetic Resonance Imaging, Cine
  • Image Processing, Computer-Assisted
  • Female
  • Artifacts