Skip to main content
Journal cover image

Negative pressure devices in the explanted penile prosthesis population.

Publication ,  Journal Article
Moul, JW; McLeod, DG
Published in: J Urol
September 1989

Of 402 penile prosthesis implanted at our institution between 1980 and 1987, 20 required explantation due to infection, erosion, pain or tissue necrosis. Of these 20 patients 14 were available for a prospective trial using a negative pressure device in an attempt to restore potency. Among these 14 patients 11 used the device at home for a minimum of 30 days after an acceptable office demonstration. Three patients did not desire the negative pressure device after an office visit test. Of the 11 home users 10 (91 per cent) reported at least satisfactory erections and successful intercourse. Interestingly, 5 of 6 patients in whom explantation was due to infection were able to use the negative pressure device successfully. Over-all, 10 of the 14 explant patients (71 per cent) engaged in regular successful intercourse using the device. The negative-pressure device can be a useful therapy for erectile impotence even in the sometimes challenging explant population. Despite previous corporeal infection and presumed fibrosis, negative pressure devices can provide patients with a functional erection-like state.

Duke Scholars

Published In

J Urol

DOI

ISSN

0022-5347

Publication Date

September 1989

Volume

142

Issue

3

Start / End Page

729 / 731

Location

United States

Related Subject Headings

  • Urology & Nephrology
  • Suction
  • Reoperation
  • Prosthesis Failure
  • Prostheses and Implants
  • Penis
  • Penile Erection
  • Middle Aged
  • Male
  • Ligation
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Moul, J. W., & McLeod, D. G. (1989). Negative pressure devices in the explanted penile prosthesis population. J Urol, 142(3), 729–731. https://doi.org/10.1016/s0022-5347(17)38869-9
Moul, J. W., and D. G. McLeod. “Negative pressure devices in the explanted penile prosthesis population.J Urol 142, no. 3 (September 1989): 729–31. https://doi.org/10.1016/s0022-5347(17)38869-9.
Moul JW, McLeod DG. Negative pressure devices in the explanted penile prosthesis population. J Urol. 1989 Sep;142(3):729–31.
Moul, J. W., and D. G. McLeod. “Negative pressure devices in the explanted penile prosthesis population.J Urol, vol. 142, no. 3, Sept. 1989, pp. 729–31. Pubmed, doi:10.1016/s0022-5347(17)38869-9.
Moul JW, McLeod DG. Negative pressure devices in the explanted penile prosthesis population. J Urol. 1989 Sep;142(3):729–731.
Journal cover image

Published In

J Urol

DOI

ISSN

0022-5347

Publication Date

September 1989

Volume

142

Issue

3

Start / End Page

729 / 731

Location

United States

Related Subject Headings

  • Urology & Nephrology
  • Suction
  • Reoperation
  • Prosthesis Failure
  • Prostheses and Implants
  • Penis
  • Penile Erection
  • Middle Aged
  • Male
  • Ligation