Skip to main content
Journal cover image

Prospective measurement of patient exposure to radiation during pediatric ureteroscopy.

Publication ,  Journal Article
Kokorowski, PJ; Chow, JS; Strauss, K; Pennison, M; Routh, JC; Nelson, CP
Published in: J Urol
April 2012

PURPOSE: Few data have been reported regarding radiation exposure during pediatric endourological procedures, including ureteroscopy. We measured radiation exposure during pediatric ureteroscopy and identify opportunities for exposure reduction. MATERIALS AND METHODS: We prospectively observed ureteroscopy procedures as part of a quality improvement initiative. Preoperative patient characteristics, operative factors, fluoroscopy settings and radiation exposure were recorded. Our outcomes were entrance skin dose and midline dose (both mGy). Specific modifiable factors were identified as targets for potential quality improvement. RESULTS: Direct observation was performed in 54 consecutive ureteroscopy procedures. Mean±SD patient age was 14.8±3.8 years (range 7.4 to 19.2), with 9 children being younger than 12 years. Mean±SD entrance skin dose was 46.4±48 mGy. Mean±SD midline dose was 6.2±5.0 mGy. The most important major determinant of radiation dose was total fluoroscopy time (mean±SD 2.68±1.8 minutes) followed by dose rate setting, child anteroposterior diameter and source to skin distance (all p<0.01). Analysis of factors affecting exposure levels revealed that use of ureteral access sheaths (p=0.01) and retrograde pyelography (p=0.04) were significantly associated with fluoroscopy time. We also found that dose rate settings were higher than recommended in up to 43% of cases and ideal C-arm positioning could have reduced exposure by 14% (up to 49% in some cases). CONCLUSIONS: Children receive biologically significant radiation doses during ureteroscopy procedures. Several modifiable factors contribute to dose and could be targeted in efforts to implement dose reduction strategies.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Urol

DOI

EISSN

1527-3792

Publication Date

April 2012

Volume

187

Issue

4

Start / End Page

1408 / 1414

Location

United States

Related Subject Headings

  • Urology & Nephrology
  • Ureteroscopy
  • Radiation Injuries
  • Radiation Dosage
  • Quality Improvement
  • Prospective Studies
  • Humans
  • Child
  • Adolescent
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kokorowski, P. J., Chow, J. S., Strauss, K., Pennison, M., Routh, J. C., & Nelson, C. P. (2012). Prospective measurement of patient exposure to radiation during pediatric ureteroscopy. J Urol, 187(4), 1408–1414. https://doi.org/10.1016/j.juro.2011.12.013
Kokorowski, Paul J., Jeanne S. Chow, Keith Strauss, Melanie Pennison, Jonathan C. Routh, and Caleb P. Nelson. “Prospective measurement of patient exposure to radiation during pediatric ureteroscopy.J Urol 187, no. 4 (April 2012): 1408–14. https://doi.org/10.1016/j.juro.2011.12.013.
Kokorowski PJ, Chow JS, Strauss K, Pennison M, Routh JC, Nelson CP. Prospective measurement of patient exposure to radiation during pediatric ureteroscopy. J Urol. 2012 Apr;187(4):1408–14.
Kokorowski, Paul J., et al. “Prospective measurement of patient exposure to radiation during pediatric ureteroscopy.J Urol, vol. 187, no. 4, Apr. 2012, pp. 1408–14. Pubmed, doi:10.1016/j.juro.2011.12.013.
Kokorowski PJ, Chow JS, Strauss K, Pennison M, Routh JC, Nelson CP. Prospective measurement of patient exposure to radiation during pediatric ureteroscopy. J Urol. 2012 Apr;187(4):1408–1414.
Journal cover image

Published In

J Urol

DOI

EISSN

1527-3792

Publication Date

April 2012

Volume

187

Issue

4

Start / End Page

1408 / 1414

Location

United States

Related Subject Headings

  • Urology & Nephrology
  • Ureteroscopy
  • Radiation Injuries
  • Radiation Dosage
  • Quality Improvement
  • Prospective Studies
  • Humans
  • Child
  • Adolescent
  • 3202 Clinical sciences