Skip to main content

Effectiveness of Glycerol Mono-oleate as a Biosealant.

Publication ,  Journal Article
Adams, GL; Manson, RJ; Giangiacomo, DM; Fronheiser, L; McCall, S; Nightingale, R; Hasselblad, V; Shaw, LK; Milton, L; Lawson, JH
Published in: J Invasive Cardiol
January 2008

BACKGROUND: The number of femoral artery catheterizations will increase over the next decade to more than 9 million worldwide. Accordingly, a new era of access site management with vascular closure techniques utilizing biologics are being developed and implemented. Glycerol mono-oleate (GMO) is one such biologic - a biodegradable compound that changes from a solid phase to a bioadhesive swollen semisolid phase when exposed to aqueous solutions and heat. We assessed whether GMO would: 1) achieve hemostasis more effectively than control when injected into a swine liver biopsy tract; and 2) inhibit common percutaneous procedure pathogens. METHODS: During the hemostasis experiment, seven swine anticoagulated with heparin (ACT > 250) underwent 10 open-liver biopsies with a 14 gauge cutting needle; 5 injected with GMO (treatment) and 5 injected with nothing (control). Thirty seconds, 2 minutes, 5 minutes and 10 minutes after the procedure, bleeding was objectively graded; 0 = no bleeding (success) and 1 = bleeding (failure). During the bacteria experiment, GMO was injected into plates containing culture media for 4 common percutaneous pathogens (Enteroccocis faecalis, Staphylococcus aureus, Escherichia coli, and Klebsiella pneumoniae). When injected, GMO converted to a semisolid phase with definitive margins in the culture media. Each bacterium was then coated over their respective media and GMO. RESULTS: The results showed a significant treatment effect (p < 0.017) on each success/failure bleeding outcome at 30 seconds (p < 0.0001), 2 minutes (p < 0.0001) and 5 minutes (p = 0.0038) based on a multiple logistic regression analysis controlling for initial bleeding, pig and side-of-liver biopsy (medial or lateral lobe). At 10 minutes, the bleeding results were not significant (p = 0.0917), likely explained by a pig's innate ability to clot at this time period. For the bacteria experiment, there was no growth of bacteria on the GMO for any of the plates. Specifically, the Staphylococcus aureus plate displayed a 200 micron halo containing no bacterial growth surrounding the GMO. CONCLUSION: In conclusion, these results illustrate a significant hemostatic effect post liver biopsy at multiple time points using GMO. Furthermore, GMO displays bacterial deterrent properties.

Duke Scholars

Published In

J Invasive Cardiol

EISSN

1557-2501

Publication Date

January 2008

Volume

20

Issue

1

Start / End Page

29 / 34

Location

United States

Related Subject Headings

  • Tissue Adhesives
  • Swine
  • Sensitivity and Specificity
  • Random Allocation
  • Probability
  • Liver
  • Hemostatics
  • Hemostatic Techniques
  • Hemorrhage
  • Glycerides
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Adams, G. L., Manson, R. J., Giangiacomo, D. M., Fronheiser, L., McCall, S., Nightingale, R., … Lawson, J. H. (2008). Effectiveness of Glycerol Mono-oleate as a Biosealant. J Invasive Cardiol, 20(1), 29–34.
Adams, George L., Roberto J. Manson, Dana M. Giangiacomo, Lucy Fronheiser, Shannon McCall, Roger Nightingale, Vic Hasselblad, Linda K. Shaw, Luther Milton, and Jeffrey H. Lawson. “Effectiveness of Glycerol Mono-oleate as a Biosealant.J Invasive Cardiol 20, no. 1 (January 2008): 29–34.
Adams GL, Manson RJ, Giangiacomo DM, Fronheiser L, McCall S, Nightingale R, et al. Effectiveness of Glycerol Mono-oleate as a Biosealant. J Invasive Cardiol. 2008 Jan;20(1):29–34.
Adams, George L., et al. “Effectiveness of Glycerol Mono-oleate as a Biosealant.J Invasive Cardiol, vol. 20, no. 1, Jan. 2008, pp. 29–34.
Adams GL, Manson RJ, Giangiacomo DM, Fronheiser L, McCall S, Nightingale R, Hasselblad V, Shaw LK, Milton L, Lawson JH. Effectiveness of Glycerol Mono-oleate as a Biosealant. J Invasive Cardiol. 2008 Jan;20(1):29–34.

Published In

J Invasive Cardiol

EISSN

1557-2501

Publication Date

January 2008

Volume

20

Issue

1

Start / End Page

29 / 34

Location

United States

Related Subject Headings

  • Tissue Adhesives
  • Swine
  • Sensitivity and Specificity
  • Random Allocation
  • Probability
  • Liver
  • Hemostatics
  • Hemostatic Techniques
  • Hemorrhage
  • Glycerides