Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy.

Publication ,  Journal Article
Gopan, O; Wu, Q
Published in: Int J Radiat Oncol Biol Phys
October 1, 2012

PURPOSE: To evaluate the accuracy of three-dimensional (3D) surface imaging system (AlignRT) registration algorithms for head-and-neck cancer patient setup during radiotherapy. METHODS AND MATERIALS: Eleven patients, each undergoing six repeated weekly helical computed tomography (CT) scans during treatment course (total 77 CTs including planning CT), were included in the study. Patient surface images used in AlignRT registration were not captured by the 3D cameras; instead, they were derived from skin contours from these CTs, thereby eliminating issues with immobilization masks. The results from surface registrations in AlignRT based on CT skin contours were compared to those based on bony anatomy registrations in Pinnacle(3), which was considered the gold standard. Both rigid and nonrigid types of setup errors were analyzed, and the effect of tumor shrinkage was investigated. RESULTS: The maximum registration errors in AlignRT were 0.2° for rotations and 0.7 mm for translations in all directions. The rigid alignment accuracy in the head region when applied to actual patient data was 1.1°, 0.8°, and 2.2° in rotation and 4.5, 2.7, and 2.4 mm in translation along the vertical, longitudinal, and lateral axes at 90% confidence level. The accuracy was affected by the patient's weight loss during treatment course, which was patient specific. Selectively choosing surface regions improved registration accuracy. The discrepancy for nonrigid registration was much larger at 1.9°, 2.4°, and 4.5° and 10.1, 11.9, and 6.9 mm at 90% confidence level. CONCLUSIONS: The 3D surface imaging system is capable of detecting rigid setup errors with good accuracy for head-and-neck cancer. Further investigations are needed to improve the accuracy in detecting nonrigid setup errors.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Int J Radiat Oncol Biol Phys

DOI

EISSN

1879-355X

Publication Date

October 1, 2012

Volume

84

Issue

2

Start / End Page

547 / 552

Location

United States

Related Subject Headings

  • Tumor Burden
  • Tomography, Spiral Computed
  • Skin
  • Radiotherapy, Image-Guided
  • Radiotherapy Setup Errors
  • Radiotherapy Planning, Computer-Assisted
  • Oncology & Carcinogenesis
  • Humans
  • Head and Neck Neoplasms
  • Facial Bones
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gopan, O., & Wu, Q. (2012). Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy. Int J Radiat Oncol Biol Phys, 84(2), 547–552. https://doi.org/10.1016/j.ijrobp.2011.12.004
Gopan, Olga, and Qiuwen Wu. “Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy.Int J Radiat Oncol Biol Phys 84, no. 2 (October 1, 2012): 547–52. https://doi.org/10.1016/j.ijrobp.2011.12.004.
Gopan, Olga, and Qiuwen Wu. “Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy.Int J Radiat Oncol Biol Phys, vol. 84, no. 2, Oct. 2012, pp. 547–52. Pubmed, doi:10.1016/j.ijrobp.2011.12.004.
Journal cover image

Published In

Int J Radiat Oncol Biol Phys

DOI

EISSN

1879-355X

Publication Date

October 1, 2012

Volume

84

Issue

2

Start / End Page

547 / 552

Location

United States

Related Subject Headings

  • Tumor Burden
  • Tomography, Spiral Computed
  • Skin
  • Radiotherapy, Image-Guided
  • Radiotherapy Setup Errors
  • Radiotherapy Planning, Computer-Assisted
  • Oncology & Carcinogenesis
  • Humans
  • Head and Neck Neoplasms
  • Facial Bones