PURPOSE: A nonlinear system reconstruction can theoretically provide timely system reconstruction when designing a real-time image-guided adaptive control for multisource heating for hyperthermia. This clinical need motivates an analysis of the essential mathematical characteristics and constraints of such an approach. METHODS: The implicit function theorem (IFT), the Karush-Kuhn-Tucker (KKT) necessary condition of optimality, and the Tikhonov-Phillips regularization (TPR) were used to analyze and determine the requirements of the optimal system reconstruction. Two mutually exclusive generic approaches were analyzed to reconstruct the physical system: The traditional full reconstruction and the recently suggested partial reconstruction. Rigorous mathematical analysis based on IFT, KKT, and TPR was provided for all four possible nonlinear reconstructions: (1) Nonlinear noiseless full reconstruction, (2) nonlinear noisy full reconstruction, (3) nonlinear noiseless partial reconstruction, and (4) nonlinear noisy partial reconstruction, when a class of nonlinear formulations of system reconstruction is employed. RESULTS: Effective numerical algorithms for solving each of the aforementioned four nonlinear reconstructions were introduced and formal derivations and analyses were provided. The analyses revealed the necessity of adding regularization when partial reconstruction is used. Regularization provides the theoretical support for one to uniquely reconstruct the optimal system. It also helps alleviate the negative influences of unavoidable measurement noise. Both theoretical analysis and numerical examples showed the importance of having a good initial guess for accomplishing nonlinear system reconstruction. CONCLUSIONS: Regularization is mandatory for partial reconstruction to make it well posed. The Tikhonov-Phillips regularized Gauss-Newton algorithm has nice theoretical performance for partial reconstruction of systems with and without noise. The Levenberg-Marquardt algorithm is a more robust algorithmic option compared to the Gauss-Newton algorithm for nonlinear full reconstruction. A severe limitation of nonlinear reconstruction is the time consuming calculations required for the derivatives of temperatures to unknowns. Developing a method of model reduction or implementing a parallel algorithm can resolve this. The results provided herein are applicable to hyperthermia with blood perfusion nonlinearly depending on temperature and in the presence of thermally significant blood vessels.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

March 2010

Volume

37

Issue

3

Start / End Page

980 / 994

Location

United States

Related Subject Headings

  • Therapy, Computer-Assisted
  • Nuclear Medicine & Medical Imaging
  • Nonlinear Dynamics
  • Neoplasms
  • Models, Biological
  • Image Interpretation, Computer-Assisted
  • Hyperthermia, Induced
  • Humans
  • Computer Simulation
  • Algorithms
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cheng, K.-S., Dewhirst, M. W., Stauffer, P. F., & Das, S. (2010). Mathematical formulation and analysis of the nonlinear system reconstruction of the online image-guided adaptive control of hyperthermia. Med Phys, 37(3), 980–994. https://doi.org/10.1118/1.3298005
Cheng, Kung-Shan, Mark W. Dewhirst, Paul F. Stauffer, and Shiva Das. “Mathematical formulation and analysis of the nonlinear system reconstruction of the online image-guided adaptive control of hyperthermia.Med Phys 37, no. 3 (March 2010): 980–94. https://doi.org/10.1118/1.3298005.
Cheng, Kung-Shan, et al. “Mathematical formulation and analysis of the nonlinear system reconstruction of the online image-guided adaptive control of hyperthermia.Med Phys, vol. 37, no. 3, Mar. 2010, pp. 980–94. Pubmed, doi:10.1118/1.3298005.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

March 2010

Volume

37

Issue

3

Start / End Page

980 / 994

Location

United States

Related Subject Headings

  • Therapy, Computer-Assisted
  • Nuclear Medicine & Medical Imaging
  • Nonlinear Dynamics
  • Neoplasms
  • Models, Biological
  • Image Interpretation, Computer-Assisted
  • Hyperthermia, Induced
  • Humans
  • Computer Simulation
  • Algorithms