Measurement of the presampling modulation transfer function of film digitizers using a curve fitting technique.

Publication ,  Journal Article
Yin, FF; Giger, ML; Doi, K
Published in: Med Phys
1990

A curve fitting technique combined with an angulated slit image has been developed for the measurement of the presampling modulation transfer function (MTF) of film digitizers. The noisy line spread functions (LSFs) acquired from an angulated slit image are fitted using a combination of two functions by means of a nonlinear least-square fitting technique. The parameters in the model function for each LSF are obtained by minimizing the residual root mean square (RMS), and then averaged over all the LSF fittings. The resulting analytical function is representative of the continuous presampled LSF. We have found that a combination of Gaussian and exponential functions provides a good fit to the LSFs obtained with film digitizers. The corresponding analytical Fourier transformation of the model function yields the presampling MTF, without Nyquist frequency limitation. Measurements of spatial resolution properties using this method were performed for two laser scanners and an optical drum scanner.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

1990

Volume

17

Issue

6

Start / End Page

962 / 966

Location

United States

Related Subject Headings

  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Models, Statistical
  • Humans
  • Biophysics
  • Biophysical Phenomena
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Yin, F. F., Giger, M. L., & Doi, K. (1990). Measurement of the presampling modulation transfer function of film digitizers using a curve fitting technique. Med Phys, 17(6), 962–966. https://doi.org/10.1118/1.596463
Yin, F. F., M. L. Giger, and K. Doi. “Measurement of the presampling modulation transfer function of film digitizers using a curve fitting technique.Med Phys 17, no. 6 (1990): 962–66. https://doi.org/10.1118/1.596463.
Yin, F. F., et al. “Measurement of the presampling modulation transfer function of film digitizers using a curve fitting technique.Med Phys, vol. 17, no. 6, 1990, pp. 962–66. Pubmed, doi:10.1118/1.596463.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

1990

Volume

17

Issue

6

Start / End Page

962 / 966

Location

United States

Related Subject Headings

  • Radiographic Image Enhancement
  • Nuclear Medicine & Medical Imaging
  • Models, Statistical
  • Humans
  • Biophysics
  • Biophysical Phenomena
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering