Skip to main content
Journal cover image

Dosimetric comparison of 6 MV and 15 MV single arc rapidarc to helical TomoTherapy for the treatment of pancreatic cancer.

Publication ,  Journal Article
Cai, J; Yue, J; McLawhorn, R; Yang, W; Wijesooriya, K; Dunlap, NE; Sheng, K; Yin, F-F; Benedict, SH
Published in: Med Dosim
2011

We conducted a planning study to compare Varian's RapidArc (RA) and helical TomoTherapy (HT) for the treatment of pancreatic cancer. Three intensity-modulated radiotherapy (IMRT) plans were generated for 8 patients with pancreatic cancer: one using HT with 6-MV beam (Plan_(HT6)), one using single-arc RA with 6-MV beam (Plan_(RA6)), and one using single-arc RA with 15-MV beam (Plan_(RA15)). Dosimetric indices including high/low conformality index (CI(100%)/CI(50%)), heterogeneity index (HI), monitor units (MUs), and doses to organs at risk (OARs) were compared. The mean CI(100%) was statistically equivalent with respect to the 2 treatment techniques, as well as beam energy (0.99, 1.01, and 1.02 for Plan_(HT6), Plan_(RA6), and Plan_(RA156,) respectively). The CI(50%) and HI were improved in both RA plans over the HT plan. The RA plans significantly reduced MU (MU(RA6) = 697, MU(RA15) = 548) compared with HT (MU(HT6) = 6177, p = 0.008 in both cases). The mean maximum cord dose was decreased from 29.6 Gy in Plan_(HT6) to 21.6 Gy (p = 0.05) in Plan_(RA6) and 21.7 Gy (p = 0.04) in Plan_(RA15). The mean bowel dose decreased from 17.2 Gy in Plan_(HT6) to 15.2 Gy (p = 0.03) in Plan_(RA6) and 15.0 Gy (p = 0.03) Plan_(RA15). The mean liver dose decreased from 8.4 Gy in Plan_(HT6) to 6.3 Gy (p = 0.04) in Plan_(RA6) and 6.2 Gy in Plan_(RA15). Variations of the mean dose to the duodenum, kidneys, and stomach were statistically insignificant. RA and HT can both deliver conformal dose distributions to target volumes while limiting the dose to surrounding OARs in the treatment of pancreatic cancer. Dosimetric advantages might be gained by using RA over HT by reducing the dose to OARs and total MUs used for treatment.

Duke Scholars

Published In

Med Dosim

DOI

EISSN

1873-4022

Publication Date

2011

Volume

36

Issue

3

Start / End Page

317 / 320

Location

United States

Related Subject Headings

  • Tomography, Spiral Computed
  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Pancreatic Neoplasms
  • Oncology & Carcinogenesis
  • Middle Aged
  • Male
  • Humans
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cai, J., Yue, J., McLawhorn, R., Yang, W., Wijesooriya, K., Dunlap, N. E., … Benedict, S. H. (2011). Dosimetric comparison of 6 MV and 15 MV single arc rapidarc to helical TomoTherapy for the treatment of pancreatic cancer. Med Dosim, 36(3), 317–320. https://doi.org/10.1016/j.meddos.2010.07.002
Cai, Jing, Jinbo Yue, Robert McLawhorn, Wensha Yang, Krishni Wijesooriya, Neal E. Dunlap, Ke Sheng, Fang-Fang Yin, and Stanley H. Benedict. “Dosimetric comparison of 6 MV and 15 MV single arc rapidarc to helical TomoTherapy for the treatment of pancreatic cancer.Med Dosim 36, no. 3 (2011): 317–20. https://doi.org/10.1016/j.meddos.2010.07.002.
Cai J, Yue J, McLawhorn R, Yang W, Wijesooriya K, Dunlap NE, et al. Dosimetric comparison of 6 MV and 15 MV single arc rapidarc to helical TomoTherapy for the treatment of pancreatic cancer. Med Dosim. 2011;36(3):317–20.
Cai, Jing, et al. “Dosimetric comparison of 6 MV and 15 MV single arc rapidarc to helical TomoTherapy for the treatment of pancreatic cancer.Med Dosim, vol. 36, no. 3, 2011, pp. 317–20. Pubmed, doi:10.1016/j.meddos.2010.07.002.
Cai J, Yue J, McLawhorn R, Yang W, Wijesooriya K, Dunlap NE, Sheng K, Yin F-F, Benedict SH. Dosimetric comparison of 6 MV and 15 MV single arc rapidarc to helical TomoTherapy for the treatment of pancreatic cancer. Med Dosim. 2011;36(3):317–320.
Journal cover image

Published In

Med Dosim

DOI

EISSN

1873-4022

Publication Date

2011

Volume

36

Issue

3

Start / End Page

317 / 320

Location

United States

Related Subject Headings

  • Tomography, Spiral Computed
  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Pancreatic Neoplasms
  • Oncology & Carcinogenesis
  • Middle Aged
  • Male
  • Humans
  • Female