Skip to main content
Journal cover image

N2 fixation estimates in real-time by cavity ring-down laser absorption spectroscopy

Publication ,  Journal Article
Cassar, ; Bellenger, JP; Jackson, RB; Karr, J; Barnett, BA
Published in: Oecologia
2012

The most common currency for estimating N(2) fixation is acetylene reduction to ethylene. Real-time estimates of nitrogen fixation are needed to close the global nitrogen budget and these remain a critical gap in both laboratory and field experiments. We present a new method for continuous real-time measurements of ethylene production: Acetylene Reduction Assays by Cavity ring-down laser Absorption Spectroscopy (ARACAS). In ARACAS, air in the headspace of an incubation chamber is circulated with a diaphragm pump through a cavity ring-down ethylene spectrometer and back to the incubation chamber. This paper describes the new approach and its benefits compared to the conventional detection of ethylene by flame ionization detector gas chromatography. First, the detection of acetylene reduction to ethylene is non-intrusive and chemically non-destructive, allowing for real-time measurements of nitrogenase activity. Second, the measurements are made instantaneously and continuously at ppb levels, allowing for observation of real-time kinetics on time intervals as short as a few seconds. Third, the instrument can be automated for long time periods of measurement. Finally, the technique will be widely accessible by the research community as it can be readily adapted to most existing acetylene reduction protocols and is based on a modestly priced, commercially available instrument. We illustrate its use for measuring N(2) fixation using two species, the diazotrophic bacterium Azotobacter vinelandii and the lichen Peltigera praetextata. We also discuss potential limitations of the approach, primarily the implications of leaks in the analyzer, as well as future improvements.

Duke Scholars

Published In

Oecologia

DOI

EISSN

1432-1939

ISSN

0029-8549

Publication Date

2012

Volume

168

Issue

2

Start / End Page

335 / 342

Related Subject Headings

  • Spectrum Analysis
  • Nitrogen Fixation
  • Kinetics
  • Ecology
  • Azotobacter vinelandii
  • Acetylene
  • 3109 Zoology
  • 3104 Evolutionary biology
  • 3103 Ecology
  • 0602 Ecology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cassar, ., Bellenger, J. P., Jackson, R. B., Karr, J., & Barnett, B. A. (2012). N2 fixation estimates in real-time by cavity ring-down laser absorption spectroscopy. Oecologia, 168(2), 335–342. https://doi.org/10.1007/s00442-011-2105-y
Cassar, T. A., J. P. Bellenger, R. B. Jackson, J. Karr, and B. A. Barnett. “N2 fixation estimates in real-time by cavity ring-down laser absorption spectroscopy.” Oecologia 168, no. 2 (2012): 335–42. https://doi.org/10.1007/s00442-011-2105-y.
Cassar, Bellenger JP, Jackson RB, Karr J, Barnett BA. N2 fixation estimates in real-time by cavity ring-down laser absorption spectroscopy. Oecologia. 2012;168(2):335–42.
Cassar, T. A., et al. “N2 fixation estimates in real-time by cavity ring-down laser absorption spectroscopy.” Oecologia, vol. 168, no. 2, 2012, pp. 335–42. Manual, doi:10.1007/s00442-011-2105-y.
Cassar, Bellenger JP, Jackson RB, Karr J, Barnett BA. N2 fixation estimates in real-time by cavity ring-down laser absorption spectroscopy. Oecologia. 2012;168(2):335–342.
Journal cover image

Published In

Oecologia

DOI

EISSN

1432-1939

ISSN

0029-8549

Publication Date

2012

Volume

168

Issue

2

Start / End Page

335 / 342

Related Subject Headings

  • Spectrum Analysis
  • Nitrogen Fixation
  • Kinetics
  • Ecology
  • Azotobacter vinelandii
  • Acetylene
  • 3109 Zoology
  • 3104 Evolutionary biology
  • 3103 Ecology
  • 0602 Ecology