Efficacy of saline vs heparin in maintaining 24-gauge intermittent intravenous catheters in a rabbit model.

Publication ,  Journal Article
Kyle, LA; Turner, BS
Published in: Neonatal network : NN
September 1999

The purpose of this study was to compare saline and heparin flushes in 24-gauge i.v. catheters.A double-blind experiment in four recorded trials was conducted using a rabbit model. Twenty-four-gauge catheters were placed in both auricle veins, and all catheters were secured in the same manner. Ampicillin was infused into each ear at the same interval, with each ear randomized to receive either the heparin solution or the saline solution.The subjects were ten white New Zealand rabbits. Data were collected on 76 catheter sites.Patency for each catheter was measured in hours and evaluated based on presence of warmth, erythema, induration, leakage, or occlusion.There was no significant difference in the duration of patency of the catheters between the two groups.

Duke Scholars

Published In

Neonatal network : NN

DOI

EISSN

1539-2880

ISSN

0730-0832

Publication Date

September 1999

Volume

18

Issue

6

Start / End Page

49 / 54

Related Subject Headings

  • Therapeutic Irrigation
  • Sodium Chloride
  • Rabbits
  • Heparin
  • Equipment Failure
  • Equipment Design
  • Double-Blind Method
  • Disease Models, Animal
  • Catheters, Indwelling
  • Catheterization, Peripheral
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kyle, L. A., & Turner, B. S. (1999). Efficacy of saline vs heparin in maintaining 24-gauge intermittent intravenous catheters in a rabbit model. Neonatal Network : NN, 18(6), 49–54. https://doi.org/10.1891/0730-0832.18.6.49
Kyle, L. A., and B. S. Turner. “Efficacy of saline vs heparin in maintaining 24-gauge intermittent intravenous catheters in a rabbit model.Neonatal Network : NN 18, no. 6 (September 1999): 49–54. https://doi.org/10.1891/0730-0832.18.6.49.
Kyle, L. A., and B. S. Turner. “Efficacy of saline vs heparin in maintaining 24-gauge intermittent intravenous catheters in a rabbit model.Neonatal Network : NN, vol. 18, no. 6, Sept. 1999, pp. 49–54. Epmc, doi:10.1891/0730-0832.18.6.49.

Published In

Neonatal network : NN

DOI

EISSN

1539-2880

ISSN

0730-0832

Publication Date

September 1999

Volume

18

Issue

6

Start / End Page

49 / 54

Related Subject Headings

  • Therapeutic Irrigation
  • Sodium Chloride
  • Rabbits
  • Heparin
  • Equipment Failure
  • Equipment Design
  • Double-Blind Method
  • Disease Models, Animal
  • Catheters, Indwelling
  • Catheterization, Peripheral