Skip to main content
Journal cover image

Improving the temporal resolution of functional MR imaging using keyhole techniques.

Publication ,  Journal Article
Gao, JH; Xiong, J; Lai, S; Haacke, EM; Woldorff, MG; Li, J; Fox, PT
Published in: Magn Reson Med
June 1996

Using a keyhole technique, it is shown that the data acquisition rate of gradient-echo imaging for functional MRI (fMRI) studies can be increased substantially. The resulting enhancement of the temporal resolution of fMRIs was accomplished without modifying the hardware of a conventional MRI system. High spatial resolution fMRI images were first collected with conventional full k-space acquisition and image reconstruction. Using the same data set, simulation reconstruction using the keyhole principle and zero-padding were performed for comparison with the full k-space reconstruction. No significant changes were found for fMRI images generated from the keyhole technique with a data sharing profile of 50% of the k-space. As k-space data sharing profiles increased to 75 and 87.5%, the keyhole fMRI images began to show only modest changes in activation intensity and area compared with the standard images. In contrast, zero-padding fMRI images produced a significant disparity both in activation intensity and area relative to the truly high-resolution fMRI images. The keyhole technique's ability to retain the intensity and area of fMRI information, while substantially reducing acquisition time, makes it a promising method for fMRI studies.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

June 1996

Volume

35

Issue

6

Start / End Page

854 / 860

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Motor Cortex
  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Artifacts
  • Adult
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gao, J. H., Xiong, J., Lai, S., Haacke, E. M., Woldorff, M. G., Li, J., & Fox, P. T. (1996). Improving the temporal resolution of functional MR imaging using keyhole techniques. Magn Reson Med, 35(6), 854–860. https://doi.org/10.1002/mrm.1910350611
Gao, J. H., J. Xiong, S. Lai, E. M. Haacke, M. G. Woldorff, J. Li, and P. T. Fox. “Improving the temporal resolution of functional MR imaging using keyhole techniques.Magn Reson Med 35, no. 6 (June 1996): 854–60. https://doi.org/10.1002/mrm.1910350611.
Gao JH, Xiong J, Lai S, Haacke EM, Woldorff MG, Li J, et al. Improving the temporal resolution of functional MR imaging using keyhole techniques. Magn Reson Med. 1996 Jun;35(6):854–60.
Gao, J. H., et al. “Improving the temporal resolution of functional MR imaging using keyhole techniques.Magn Reson Med, vol. 35, no. 6, June 1996, pp. 854–60. Pubmed, doi:10.1002/mrm.1910350611.
Gao JH, Xiong J, Lai S, Haacke EM, Woldorff MG, Li J, Fox PT. Improving the temporal resolution of functional MR imaging using keyhole techniques. Magn Reson Med. 1996 Jun;35(6):854–860.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

June 1996

Volume

35

Issue

6

Start / End Page

854 / 860

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Motor Cortex
  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Artifacts
  • Adult
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering