The main building block and readout unit of the planned CDF Run lib silicon detector is a "stave," a highly integrated mechanical, thermal, and electrical structure. One of its characteristic features is a copper-on-Kapton flexible cable for power, high voltage, data transmission, and control signals that is placed directly below the silicon microstrip sensors. The dense packaging makes deadtime-less operation of the stave a challenge since coupling of bus cable activity into the silicon sensors must be suppressed efficiently. The stave design features relevant for deadtime-less operation are discussed. The electrical performance achieved with stave prototypes is presented.

Duke Scholars

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

June 1, 2004

Volume

51

Issue

3 III

Start / End Page

987 / 993

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Akimoto, T., Aoki, M., Azzi, P., Bacchetta, N., Behari, S., Benjamin, D., … Zucchelli, S. (2004). CDF run IIb silicon detector: Electrical performance and deadtime-less operation. IEEE Transactions on Nuclear Science, 51(3 III), 987–993. https://doi.org/10.1109/TNS.2004.829508
Akimoto, T., M. Aoki, P. Azzi, N. Bacchetta, S. Behari, D. Benjamin, D. Bisello, et al. “CDF run IIb silicon detector: Electrical performance and deadtime-less operation.” IEEE Transactions on Nuclear Science 51, no. 3 III (June 1, 2004): 987–93. https://doi.org/10.1109/TNS.2004.829508.
Akimoto T, Aoki M, Azzi P, Bacchetta N, Behari S, Benjamin D, et al. CDF run IIb silicon detector: Electrical performance and deadtime-less operation. IEEE Transactions on Nuclear Science. 2004 Jun 1;51(3 III):987–93.
Akimoto, T., et al. “CDF run IIb silicon detector: Electrical performance and deadtime-less operation.” IEEE Transactions on Nuclear Science, vol. 51, no. 3 III, June 2004, pp. 987–93. Scopus, doi:10.1109/TNS.2004.829508.
Akimoto T, Aoki M, Azzi P, Bacchetta N, Behari S, Benjamin D, Bisello D, Bolla G, Bortoletto D, Busetto G, Cabrera S, Canepa A, Cardoso G, Chertok M, Ciobanu CI, Derylo G, Fang I, Feng EJ, Fernandez JP, Flaugher B, Freeman J, Galtieri L, Galyardt J, Garcia-Sciveres M, Giurgiu G, Haber C, Hale D, Hara K, Harr R, Hill C, Hoff J, Holbrook B, Hong SC, Hrycyk M, Hsiung TH, Incandela J, Jeon EJ, Joo KK, Junk T, Kahkola H, Karjalainen S, Kim S, Kobayashi K, Kong DJ, Krieger B, Kruse M, Kuznetsova N, Kyre S, Lander R, Landry T, Lauhakangas R, Lee J, Lu RS, Lujan P, Lukens P, Mandelli E, Manea C, Maksimovic P, Merkel P, Min SN, Moccia S, Nakano I, Nelson T, Nord B, Novak J, Okusawa T, Orava R, Orlov Y, Osterberg K, Pantano D, Pavlicek V, Pellett D, Pursley J, Riipinen P, Schuyler B, Shenai A, Soha A, Stuart D, Tanaka R, Tavi M, Von Der Lippe H, Walder JP, Wang Z, Weber M, Wester W, Yamamoto K, Yang YC, Yao W, Yarema R, Yun JC, Zetti F, Zimmerman T, Zimmermann S, Zucchelli S. CDF run IIb silicon detector: Electrical performance and deadtime-less operation. IEEE Transactions on Nuclear Science. 2004 Jun 1;51(3 III):987–993.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

June 1, 2004

Volume

51

Issue

3 III

Start / End Page

987 / 993

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics