CDF run IIb silicon detector: Electrical performance and deadtime-less operation
Publication
, Journal Article
Akimoto, T; Aoki, M; Azzi, P; Bacchetta, N; Behari, S; Benjamin, D; Bisello, D; Bolla, G; Bortoletto, D; Busetto, G; Cabrera, S; Canepa, A ...
Published in: IEEE Transactions on Nuclear Science
June 1, 2004
The main building block and readout unit of the planned CDF Run lib silicon detector is a "stave," a highly integrated mechanical, thermal, and electrical structure. One of its characteristic features is a copper-on-Kapton flexible cable for power, high voltage, data transmission, and control signals that is placed directly below the silicon microstrip sensors. The dense packaging makes deadtime-less operation of the stave a challenge since coupling of bus cable activity into the silicon sensors must be suppressed efficiently. The stave design features relevant for deadtime-less operation are discussed. The electrical performance achieved with stave prototypes is presented.
Duke Scholars
Published In
IEEE Transactions on Nuclear Science
DOI
ISSN
0018-9499
Publication Date
June 1, 2004
Volume
51
Issue
3 III
Start / End Page
987 / 993
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0903 Biomedical Engineering
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
Citation
APA
Chicago
ICMJE
MLA
NLM
Akimoto, T., Aoki, M., Azzi, P., Bacchetta, N., Behari, S., Benjamin, D., … Zucchelli, S. (2004). CDF run IIb silicon detector: Electrical performance and deadtime-less operation. IEEE Transactions on Nuclear Science, 51(3 III), 987–993. https://doi.org/10.1109/TNS.2004.829508
Akimoto, T., M. Aoki, P. Azzi, N. Bacchetta, S. Behari, D. Benjamin, D. Bisello, et al. “CDF run IIb silicon detector: Electrical performance and deadtime-less operation.” IEEE Transactions on Nuclear Science 51, no. 3 III (June 1, 2004): 987–93. https://doi.org/10.1109/TNS.2004.829508.
Akimoto T, Aoki M, Azzi P, Bacchetta N, Behari S, Benjamin D, et al. CDF run IIb silicon detector: Electrical performance and deadtime-less operation. IEEE Transactions on Nuclear Science. 2004 Jun 1;51(3 III):987–93.
Akimoto, T., et al. “CDF run IIb silicon detector: Electrical performance and deadtime-less operation.” IEEE Transactions on Nuclear Science, vol. 51, no. 3 III, June 2004, pp. 987–93. Scopus, doi:10.1109/TNS.2004.829508.
Akimoto T, Aoki M, Azzi P, Bacchetta N, Behari S, Benjamin D, Bisello D, Bolla G, Bortoletto D, Busetto G, Cabrera S, Canepa A, Cardoso G, Chertok M, Ciobanu CI, Derylo G, Fang I, Feng EJ, Fernandez JP, Flaugher B, Freeman J, Galtieri L, Galyardt J, Garcia-Sciveres M, Giurgiu G, Haber C, Hale D, Hara K, Harr R, Hill C, Hoff J, Holbrook B, Hong SC, Hrycyk M, Hsiung TH, Incandela J, Jeon EJ, Joo KK, Junk T, Kahkola H, Karjalainen S, Kim S, Kobayashi K, Kong DJ, Krieger B, Kruse M, Kuznetsova N, Kyre S, Lander R, Landry T, Lauhakangas R, Lee J, Lu RS, Lujan P, Lukens P, Mandelli E, Manea C, Maksimovic P, Merkel P, Min SN, Moccia S, Nakano I, Nelson T, Nord B, Novak J, Okusawa T, Orava R, Orlov Y, Osterberg K, Pantano D, Pavlicek V, Pellett D, Pursley J, Riipinen P, Schuyler B, Shenai A, Soha A, Stuart D, Tanaka R, Tavi M, Von Der Lippe H, Walder JP, Wang Z, Weber M, Wester W, Yamamoto K, Yang YC, Yao W, Yarema R, Yun JC, Zetti F, Zimmerman T, Zimmermann S, Zucchelli S. CDF run IIb silicon detector: Electrical performance and deadtime-less operation. IEEE Transactions on Nuclear Science. 2004 Jun 1;51(3 III):987–993.
Published In
IEEE Transactions on Nuclear Science
DOI
ISSN
0018-9499
Publication Date
June 1, 2004
Volume
51
Issue
3 III
Start / End Page
987 / 993
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0903 Biomedical Engineering
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics