Skip to main content

Comparison of spot and band electrodes for monitoring cardiac performance by impedance cardiography during exercise

Publication ,  Journal Article
Sherwood, A; Royal, S; Turner, R; Hutcheson, S
Published in: Proceedings of the Annual Conference on Engineering in Medicine and Biology
December 1, 1991

A comfortable and convenient electrode configuration using disposable ECG electrodes for recording the impedance cardiogram was compared to the traditional band electrodes. Measurement of systolic time intervals at rest and during exercise was unaffected by the electrode configuration used. Resting cardiac output values differed significantly according to electrode type, and subtle differences in cardiac output responses to exercise were also observed.

Duke Scholars

Published In

Proceedings of the Annual Conference on Engineering in Medicine and Biology

ISSN

0589-1019

Publication Date

December 1, 1991

Volume

13

Issue

pt 2

Start / End Page

796
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Sherwood, A., Royal, S., Turner, R., & Hutcheson, S. (1991). Comparison of spot and band electrodes for monitoring cardiac performance by impedance cardiography during exercise. Proceedings of the Annual Conference on Engineering in Medicine and Biology, 13(pt 2), 796.
Sherwood, A., S. Royal, R. Turner, and S. Hutcheson. “Comparison of spot and band electrodes for monitoring cardiac performance by impedance cardiography during exercise.” Proceedings of the Annual Conference on Engineering in Medicine and Biology 13, no. pt 2 (December 1, 1991): 796.
Sherwood A, Royal S, Turner R, Hutcheson S. Comparison of spot and band electrodes for monitoring cardiac performance by impedance cardiography during exercise. Proceedings of the Annual Conference on Engineering in Medicine and Biology. 1991 Dec 1;13(pt 2):796.
Sherwood, A., et al. “Comparison of spot and band electrodes for monitoring cardiac performance by impedance cardiography during exercise.” Proceedings of the Annual Conference on Engineering in Medicine and Biology, vol. 13, no. pt 2, Dec. 1991, p. 796.
Sherwood A, Royal S, Turner R, Hutcheson S. Comparison of spot and band electrodes for monitoring cardiac performance by impedance cardiography during exercise. Proceedings of the Annual Conference on Engineering in Medicine and Biology. 1991 Dec 1;13(pt 2):796.

Published In

Proceedings of the Annual Conference on Engineering in Medicine and Biology

ISSN

0589-1019

Publication Date

December 1, 1991

Volume

13

Issue

pt 2

Start / End Page

796