Skip to main content
Journal cover image

Fiber-Optic time-resolved fluorimetry for immunoassays.

Publication ,  Journal Article
Petrea, RD; Sepaniak, MJ; Vo-Dinh, T
Published in: Talanta
February 1988

Rare-earth metal chelates used as fluorescent labels for immunoassays possess extremely long fluorescence lifetimes and permit the elective use of time-resolved detection. This is very important in fiber-optic fluorimetry, a technique that ordinarily exhibits large signal backgrounds from back-scattered radiation. With time-resolved detection to reject the back-scattered radiation, the limit of detection for Eu 2-naphthoyltrifluoroacetonate is 10(-12)M, nearly three orders of magnitude lower than for the fiber-optic measurement of the most common fluorescent label, fluorescein isothiocyanate. Commercially available reagents labeled with an europium chelate are used to demonstrate the potential utility of time-resolved fluorimetry in fiber-optic immunoassays. Rabbit immunoglobulin G (IgG) is covalently bonded to the distal end of quartz optical fibers prior to exposure to anti-rabbit IgG labelled with europium chelate. The limit of detection for the assay is approximately 0.1 mug/ml.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Talanta

DOI

EISSN

1873-3573

ISSN

0039-9140

Publication Date

February 1988

Volume

35

Issue

2

Start / End Page

139 / 144

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0399 Other Chemical Sciences
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Petrea, R. D., Sepaniak, M. J., & Vo-Dinh, T. (1988). Fiber-Optic time-resolved fluorimetry for immunoassays. Talanta, 35(2), 139–144. https://doi.org/10.1016/0039-9140(88)80052-3
Petrea, R. D., M. J. Sepaniak, and T. Vo-Dinh. “Fiber-Optic time-resolved fluorimetry for immunoassays.Talanta 35, no. 2 (February 1988): 139–44. https://doi.org/10.1016/0039-9140(88)80052-3.
Petrea RD, Sepaniak MJ, Vo-Dinh T. Fiber-Optic time-resolved fluorimetry for immunoassays. Talanta. 1988 Feb;35(2):139–44.
Petrea, R. D., et al. “Fiber-Optic time-resolved fluorimetry for immunoassays.Talanta, vol. 35, no. 2, Feb. 1988, pp. 139–44. Epmc, doi:10.1016/0039-9140(88)80052-3.
Petrea RD, Sepaniak MJ, Vo-Dinh T. Fiber-Optic time-resolved fluorimetry for immunoassays. Talanta. 1988 Feb;35(2):139–144.
Journal cover image

Published In

Talanta

DOI

EISSN

1873-3573

ISSN

0039-9140

Publication Date

February 1988

Volume

35

Issue

2

Start / End Page

139 / 144

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0399 Other Chemical Sciences
  • 0301 Analytical Chemistry