Skip to main content

Parallel-beam tilted-head analytic SPECT reconstruction

Publication ,  Journal Article
Pieper, BC; Bowsher, JE; Tornai, MP; Archer, CN; Jaszczak, RJ
Published in: IEEE Nuclear Science Symposium and Medical Imaging Conference
January 1, 2001

Parallel-beam Tilted-Head SPECT (TH-SPECT) was previously implemented on a SPECT system for its potential to image breast lesions and nearby axilla of seated, upright women. All TH-SPECT reconstructions will contain artifacts since the tilted orbit does not satisfy the Orlov sampling criteria. However, it is not clear which reconstruction method, if any, is better suited for TH-SPECT data. Here a geometric derivation of the ramp filter for tilted parallel-beam geometries is presented. A new filter is then heuristically suggested, specifically designed to boost frequencies near the unmeasured null space present in all TH-SPECT geometries. This filter, H(ν″, τ″), was combined with the ramp filter and then implemented and compared with an iterative Ordered Subsets Expectation Maximization (OSEM) algorithm and a ramp-only FBP algorithm, using TH-SPECT data. Contrast values as well as axial elongation present in all TH-SPECT reconstructions were characterized using a mini-Defrise disk phantom placed inside a fillable breast phantom and imaged from 0-15 degree head tilt. At small tilt angles about the mini-Defrise disk phantom, contrasts were generally equal between H(ν″, τ″)-filtered FBP and OSEM reconstructions compared at similar noise values, and poorer contrasts were obtained for ramp-only FBP results. In conclusion, measured results indicate OSEM reconstruction may offer better shape and uniform activity distribution of the breast compared to FBP methods. H(ν″, τ″)-filtered TH-SPECT FBP, however, performed more comparably to OSEM than ramp-only FBP methods, and other similar filtering techniques may provide even greater improvements.

Duke Scholars

Published In

IEEE Nuclear Science Symposium and Medical Imaging Conference

DOI

Publication Date

January 1, 2001

Volume

3

Start / End Page

1313 / 1317

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pieper, B. C., Bowsher, J. E., Tornai, M. P., Archer, C. N., & Jaszczak, R. J. (2001). Parallel-beam tilted-head analytic SPECT reconstruction. IEEE Nuclear Science Symposium and Medical Imaging Conference, 3, 1313–1317. https://doi.org/10.1109/TNS.2002.803781
Pieper, B. C., J. E. Bowsher, M. P. Tornai, C. N. Archer, and R. J. Jaszczak. “Parallel-beam tilted-head analytic SPECT reconstruction.” IEEE Nuclear Science Symposium and Medical Imaging Conference 3 (January 1, 2001): 1313–17. https://doi.org/10.1109/TNS.2002.803781.
Pieper BC, Bowsher JE, Tornai MP, Archer CN, Jaszczak RJ. Parallel-beam tilted-head analytic SPECT reconstruction. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2001 Jan 1;3:1313–7.
Pieper, B. C., et al. “Parallel-beam tilted-head analytic SPECT reconstruction.” IEEE Nuclear Science Symposium and Medical Imaging Conference, vol. 3, Jan. 2001, pp. 1313–17. Scopus, doi:10.1109/TNS.2002.803781.
Pieper BC, Bowsher JE, Tornai MP, Archer CN, Jaszczak RJ. Parallel-beam tilted-head analytic SPECT reconstruction. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2001 Jan 1;3:1313–1317.

Published In

IEEE Nuclear Science Symposium and Medical Imaging Conference

DOI

Publication Date

January 1, 2001

Volume

3

Start / End Page

1313 / 1317

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics