Skip to main content

Effects of pinhole material and aperture size on lesion contrast and SNR in breast SPECT

Publication ,  Journal Article
Tornai, MP; Bowsher, JE; Pieper, BC; Jaszczak, RJ
Published in: IEEE Nuclear Science Symposium and Medical Imaging Conference
December 1, 2000

Pinhole collimators made of depleted uranium-238 (DU) and tungsten alloy (VV) with aperture diameters from 1 - 4 mm were used to image <0.6 ml breast lesions in a pendulous breast reference frame, centered on the axis-of-rotation. with incomplete circular orbit (ICO <180 deg) SPECT. Breast, body and myocardial activity were included in the phantoms to simulate clinical imaging conditions. The background from the DU aperture was <12% contribution to the emission photopeak, and was inversely proportional to aperture size. Scans performed for clinical counting times included lesion:background ratios of 12:1 and 7:1. Contrast and signal-to-noise ratios (SNR) were better with smaller apertures, and measurements indicate that 2 - 3 mm apertures may have the best performance down to 0.11 ml lesions with near clinical uptake ratios of Tc-99m compounds. Contrast generally decreased for increasing aperture diameter, indicating that the enhanced spatial resolution may outweigh the loss in sensitivity in small lesion identification with ICO breast SPECT. Dedicated pinhole ICO SPECT of the breast appears to be a dramatically improved technique over conventional planar breast scintimammography, providing enhanced contrast and SNR for imaging smaller lesions with the dedicated high resolution pinholes.

Duke Scholars

Published In

IEEE Nuclear Science Symposium and Medical Imaging Conference

Publication Date

December 1, 2000

Volume

3
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tornai, M. P., Bowsher, J. E., Pieper, B. C., & Jaszczak, R. J. (2000). Effects of pinhole material and aperture size on lesion contrast and SNR in breast SPECT. IEEE Nuclear Science Symposium and Medical Imaging Conference, 3.
Tornai, M. P., J. E. Bowsher, B. C. Pieper, and R. J. Jaszczak. “Effects of pinhole material and aperture size on lesion contrast and SNR in breast SPECT.” IEEE Nuclear Science Symposium and Medical Imaging Conference 3 (December 1, 2000).
Tornai MP, Bowsher JE, Pieper BC, Jaszczak RJ. Effects of pinhole material and aperture size on lesion contrast and SNR in breast SPECT. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2000 Dec 1;3.
Tornai, M. P., et al. “Effects of pinhole material and aperture size on lesion contrast and SNR in breast SPECT.” IEEE Nuclear Science Symposium and Medical Imaging Conference, vol. 3, Dec. 2000.
Tornai MP, Bowsher JE, Pieper BC, Jaszczak RJ. Effects of pinhole material and aperture size on lesion contrast and SNR in breast SPECT. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2000 Dec 1;3.

Published In

IEEE Nuclear Science Symposium and Medical Imaging Conference

Publication Date

December 1, 2000

Volume

3