Skip to main content

Point-set registration of tagged HE-3 images using a structurally-based Jensen-Shannon divergence measure within a deterministic annealing framework

Publication ,  Journal Article
Tustison, NJ; Awate, SP; Altes, TA; Gee, JC; Cai, J; Miller, GW; De Lange, EE; Mugler, JP
Published in: 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI
September 10, 2008

Helium-3 tagged magnetic resonance imaging has demonstrated potential for calculating pulmonary deformation from medical imagery. Such measurements are useful for determining the biomechanical properties of the lung. Unfortunately, the relative facility of visually tracking deformation via the high contrast tag lines has not transferred readily to the algorithmic domain of automatically establishing tag-line correspondences. We proffer a solution to this dilemma by translating the problem into a unique point-set registration scenario. Not only does this permit capitalizing on certain spectral aspects of tagged MRI but registration can be performed within a deterministic annealing framework for decreased susceptibility to local minima. ©2008 IEEE.

Duke Scholars

Published In

2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI

DOI

Publication Date

September 10, 2008

Start / End Page

772 / 775
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tustison, N. J., Awate, S. P., Altes, T. A., Gee, J. C., Cai, J., Miller, G. W., … Mugler, J. P. (2008). Point-set registration of tagged HE-3 images using a structurally-based Jensen-Shannon divergence measure within a deterministic annealing framework. 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI, 772–775. https://doi.org/10.1109/ISBI.2008.4541110
Tustison, N. J., S. P. Awate, T. A. Altes, J. C. Gee, J. Cai, G. W. Miller, E. E. De Lange, and J. P. Mugler. “Point-set registration of tagged HE-3 images using a structurally-based Jensen-Shannon divergence measure within a deterministic annealing framework.” 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI, September 10, 2008, 772–75. https://doi.org/10.1109/ISBI.2008.4541110.
Tustison NJ, Awate SP, Altes TA, Gee JC, Cai J, Miller GW, et al. Point-set registration of tagged HE-3 images using a structurally-based Jensen-Shannon divergence measure within a deterministic annealing framework. 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI. 2008 Sep 10;772–5.
Tustison, N. J., et al. “Point-set registration of tagged HE-3 images using a structurally-based Jensen-Shannon divergence measure within a deterministic annealing framework.” 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI, Sept. 2008, pp. 772–75. Scopus, doi:10.1109/ISBI.2008.4541110.
Tustison NJ, Awate SP, Altes TA, Gee JC, Cai J, Miller GW, De Lange EE, Mugler JP. Point-set registration of tagged HE-3 images using a structurally-based Jensen-Shannon divergence measure within a deterministic annealing framework. 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI. 2008 Sep 10;772–775.

Published In

2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI

DOI

Publication Date

September 10, 2008

Start / End Page

772 / 775