Long-term outcomes of the symmetry vein graft anastomosis device: a matched case-control analysis.

Publication ,  Journal Article
Kachhy, RG; Kong, DF; Honeycutt, E; Shaw, LK; Davis, RD
Published in: Circulation
July 4, 2006

BACKGROUND: The Symmetry Bypass Connector (St. Jude Medical) was developed to rapidly anastomose saphenous vein grafts to the aorta during coronary bypass surgery (CABG) without cross-clamping. Previous uncontrolled studies of this device observed vein graft closures at six months, possibly attributable to neointimal hyperplasia. METHODS AND RESULTS: To assess the long-term clinical outcomes of the Symmetry device, we performed a retrospective matched case-control analysis of patients who underwent CABG at Duke Medical Center between January 1, 2002 and December 31, 2003. In 121 patients, at least one proximal anastomosis used a Symmetry device. Traditional suture methods were used in 178 control patients, matched by age group, gender, use of cardiopulmonary bypass, and Hannan perioperative risk score. One-year outcomes were compared using the log-rank test and Cox proportional hazards regression models. Major adverse events were more frequent among cases compared with controls. By unadjusted Kaplan-Meier analysis for the composite end point of death, nonfatal myocardial infarction, repeat cardiac catheterization, or repeat CABG, there was a trend towards increased events in the Symmetry device group (P=0.053). No significant differences were detected for stroke, all cause mortality, or the combined end point of death or nonfatal myocardial infarction. CONCLUSIONS: Use of the Symmetry Bypass Connector was associated with increased risk for major adverse events at 1 year, suggestive of early graft closure. The potential reductions in operative stroke risk (from the elimination of aortic cross-clamping) must be weighed against the potential risk for later adverse events. These findings encourage close follow-up of patients who received this device.

Duke Scholars

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

July 4, 2006

Volume

114

Issue

1 Suppl

Start / End Page

I425 / I429

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Suture Techniques
  • Survival Analysis
  • Stroke
  • Statistics, Nonparametric
  • Saphenous Vein
  • Retrospective Studies
  • Reoperation
  • Proportional Hazards Models
  • Postoperative Complications
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kachhy, R. G., Kong, D. F., Honeycutt, E., Shaw, L. K., & Davis, R. D. (2006). Long-term outcomes of the symmetry vein graft anastomosis device: a matched case-control analysis. Circulation, 114(1 Suppl), I425–I429. https://doi.org/10.1161/CIRCULATIONAHA.105.000695
Kachhy, Radha G., David F. Kong, Emily Honeycutt, Linda K. Shaw, and R Duane Davis. “Long-term outcomes of the symmetry vein graft anastomosis device: a matched case-control analysis.Circulation 114, no. 1 Suppl (July 4, 2006): I425–29. https://doi.org/10.1161/CIRCULATIONAHA.105.000695.
Kachhy RG, Kong DF, Honeycutt E, Shaw LK, Davis RD. Long-term outcomes of the symmetry vein graft anastomosis device: a matched case-control analysis. Circulation. 2006 Jul 4;114(1 Suppl):I425–9.
Kachhy, Radha G., et al. “Long-term outcomes of the symmetry vein graft anastomosis device: a matched case-control analysis.Circulation, vol. 114, no. 1 Suppl, July 2006, pp. I425–29. Pubmed, doi:10.1161/CIRCULATIONAHA.105.000695.
Kachhy RG, Kong DF, Honeycutt E, Shaw LK, Davis RD. Long-term outcomes of the symmetry vein graft anastomosis device: a matched case-control analysis. Circulation. 2006 Jul 4;114(1 Suppl):I425–I429.

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

July 4, 2006

Volume

114

Issue

1 Suppl

Start / End Page

I425 / I429

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Suture Techniques
  • Survival Analysis
  • Stroke
  • Statistics, Nonparametric
  • Saphenous Vein
  • Retrospective Studies
  • Reoperation
  • Proportional Hazards Models
  • Postoperative Complications