Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel

Fault tolerance of semiactive seismic isolation

Publication ,  Journal Article
Gavin, H; Alhan, C; Oka, N
Published in: Journal of Structural Engineering
December 1, 2003

A six-story seismically isolated structure fitted with semiactive hydraulic devices is analyzed in order to study the effect of time lag in the devices and mass eccentricity in the superstructure on the lateral-torsional behavior. The computer program 3DBASIS, which allows the nonlinear dynamic analysis of three-dimensional structures, is used in this work. Appropriate modifications were made to this program to incorporate the behavior of semiactive hydraulic devices. Three different types of base isolation systems were considered: (1) lead rubber bearings; (2) lead rubber bearings with supplemental viscous damping: and (3) lead rubber bearings with semiactive viscous damping. A comparison of these three base-isolation systems, considering both the effects of eccentricity in the structure and differential time lags in semiactive hydraulic devices are studied. The peak isolator shear, isolation drift, rotation, and torsional moment are reported. Three major earthquake motion records, namely, the El Centre record of the 1940 Imperial Valley earthquake, the Meloland record of the 1979 Imperial Valley earthquake, and the Sylmar free field record of the 1994 Northridge earthquake were used as inputs in the analyses.

Duke Scholars

Published In

Journal of Structural Engineering

DOI

ISSN

0733-9445

Publication Date

December 1, 2003

Volume

129

Issue

7

Start / End Page

922 / 932

Related Subject Headings

  • Civil Engineering
  • 4016 Materials engineering
  • 4005 Civil engineering
  • 0913 Mechanical Engineering
  • 0912 Materials Engineering
  • 0905 Civil Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gavin, H., Alhan, C., & Oka, N. (2003). Fault tolerance of semiactive seismic isolation. Journal of Structural Engineering, 129(7), 922–932. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:7(922)
Gavin, H., C. Alhan, and N. Oka. “Fault tolerance of semiactive seismic isolation.” Journal of Structural Engineering 129, no. 7 (December 1, 2003): 922–32. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:7(922).
Gavin H, Alhan C, Oka N. Fault tolerance of semiactive seismic isolation. Journal of Structural Engineering. 2003 Dec 1;129(7):922–32.
Gavin, H., et al. “Fault tolerance of semiactive seismic isolation.” Journal of Structural Engineering, vol. 129, no. 7, Dec. 2003, pp. 922–32. Scopus, doi:10.1061/(ASCE)0733-9445(2003)129:7(922).
Gavin H, Alhan C, Oka N. Fault tolerance of semiactive seismic isolation. Journal of Structural Engineering. 2003 Dec 1;129(7):922–932.

Published In

Journal of Structural Engineering

DOI

ISSN

0733-9445

Publication Date

December 1, 2003

Volume

129

Issue

7

Start / End Page

922 / 932

Related Subject Headings

  • Civil Engineering
  • 4016 Materials engineering
  • 4005 Civil engineering
  • 0913 Mechanical Engineering
  • 0912 Materials Engineering
  • 0905 Civil Engineering