Skip to main content

The development of an implantable electrochemical glucose sensor: response to glucose in bovine serum ultrafiltrate.

Publication ,  Journal Article
Guyton, JR; Soeldner, JS; Giner, J; Colton, CK; Morris, RS
Published in: Horm Metab Res Suppl
1979

A glucose sensor based on organic oxidation reactions at a platinum electrode is being developed as the key component for an implantable artificial beta cell for diabetic patients. Sensitivity of a membrane-covered platinum electrode to changing glucose concentration in bovine serum ultrafiltrate has been demonstrated, with current response as high as 60 microamperes per 100 mg/dl change in glucose concentration. Reproducibility of measurements probably will depend on satisfactory mechanical assembly of the membrane-electrode combination. An approach to selectivity based on multiple current measurements is suggested.

Duke Scholars

Published In

Horm Metab Res Suppl

ISSN

0170-5903

Publication Date

1979

Issue

8

Start / End Page

24 / 26

Location

Germany

Related Subject Headings

  • Ultrafiltration
  • Islets of Langerhans
  • Humans
  • Electrodes
  • Diabetes Mellitus
  • Cattle
  • Blood Glucose
  • Autoanalysis
  • Artificial Organs
  • Animals
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Guyton, J. R., Soeldner, J. S., Giner, J., Colton, C. K., & Morris, R. S. (1979). The development of an implantable electrochemical glucose sensor: response to glucose in bovine serum ultrafiltrate. Horm Metab Res Suppl, (8), 24–26.
Guyton, J. R., J. S. Soeldner, J. Giner, C. K. Colton, and R. S. Morris. “The development of an implantable electrochemical glucose sensor: response to glucose in bovine serum ultrafiltrate.Horm Metab Res Suppl, no. 8 (1979): 24–26.
Guyton JR, Soeldner JS, Giner J, Colton CK, Morris RS. The development of an implantable electrochemical glucose sensor: response to glucose in bovine serum ultrafiltrate. Horm Metab Res Suppl. 1979;(8):24–6.
Guyton JR, Soeldner JS, Giner J, Colton CK, Morris RS. The development of an implantable electrochemical glucose sensor: response to glucose in bovine serum ultrafiltrate. Horm Metab Res Suppl. 1979;(8):24–26.

Published In

Horm Metab Res Suppl

ISSN

0170-5903

Publication Date

1979

Issue

8

Start / End Page

24 / 26

Location

Germany

Related Subject Headings

  • Ultrafiltration
  • Islets of Langerhans
  • Humans
  • Electrodes
  • Diabetes Mellitus
  • Cattle
  • Blood Glucose
  • Autoanalysis
  • Artificial Organs
  • Animals