Skip to main content
Journal cover image

Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line.

Publication ,  Journal Article
Dhalla, A-H; Izatt, JA
Published in: Biomedical optics express
April 2011

Swept-source optical coherence tomography (SSOCT) provides a substantial sensitivity advantage over its time-domain counterpart, but suffers from a reduced imaging depth range due to sensitivity falloff and complex conjugate ambiguity. Heterodyne complex conjugate-resolved SSOCT (HCCR-SSOCT) has been previously demonstrated as a technique to completely resolve the complex conjugate ambiguity, effectively doubling the falloff limited imaging depth, without the reduction in imaging speed associated with other CCR techniques. However, previous implementations of this technique have employed expensive and lossy optical modulators to provide the required differential phase modulation. In this paper, we demonstrate the use of a dispersive optical delay line (D-ODL) as the reference arm of an OCT system to realize HCCR-SSOCT. This technique maintains the existing advantages of HCCR-SSOCT in that it completely resolves the complex conjugate artifact and does not reduce imaging speed, while conferring the additional advantages of being low cost, maintaining system sensitivity and resolution, not requiring any additional signal processing, and working at all wavelengths and imaging speeds. The D-ODL also allows for hardware correction of unbalanced dispersion in the reference and sample arm, adding further flexibility to system design. We demonstrate the technique using an SSOCT system operating at 100kHz with a central wavelength of 1040nm. Falloff measurements performed using a standard OCT configuration and the proposed D-ODL demonstrate a doubling of the effective imaging range with no sensitivity or resolution penalty. Feasibility of the technique for in vivo imaging was demonstrated by imaging the ocular anterior segments of healthy human volunteers.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Biomedical optics express

DOI

EISSN

2156-7085

ISSN

2156-7085

Publication Date

April 2011

Volume

2

Issue

5

Start / End Page

1218 / 1232

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4003 Biomedical engineering
  • 3212 Ophthalmology and optometry
  • 0912 Materials Engineering
  • 0205 Optical Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dhalla, A.-H., & Izatt, J. A. (2011). Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line. Biomedical Optics Express, 2(5), 1218–1232. https://doi.org/10.1364/boe.2.001218
Dhalla, Al-Hafeez, and Joseph A. Izatt. “Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line.Biomedical Optics Express 2, no. 5 (April 2011): 1218–32. https://doi.org/10.1364/boe.2.001218.
Dhalla, Al-Hafeez, and Joseph A. Izatt. “Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line.Biomedical Optics Express, vol. 2, no. 5, Apr. 2011, pp. 1218–32. Epmc, doi:10.1364/boe.2.001218.
Journal cover image

Published In

Biomedical optics express

DOI

EISSN

2156-7085

ISSN

2156-7085

Publication Date

April 2011

Volume

2

Issue

5

Start / End Page

1218 / 1232

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4003 Biomedical engineering
  • 3212 Ophthalmology and optometry
  • 0912 Materials Engineering
  • 0205 Optical Physics