Skip to main content

In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography.

Publication ,  Journal Article
Wang, Y; Bower, BA; Izatt, JA; Tan, O; Huang, D
Published in: Journal of biomedical optics
July 2007

There is considerable interest in new methods for the assessment of retinal blood flow for the diagnosis of eye diseases. We present in vivo normal human volumetric retinal flow measurement using Fourier domain Doppler optical coherence tomography. We used a dual-plane scanning pattern to determine the angle between the blood flow and the scanning beam in order to measure total flow velocity. Volumetric flow in each blood vessel around the optic nerve head was integrated in one cardiac cycle in each measurement. Measurements were performed in the right eye of one human subject. The measured venous flow velocity ranged from 16.26 mm/s to 29.7 mm/s. The arterial flow velocity ranged from 38.35 mm/s to 51.13 mm/s. The total retinal venous and arterial flow both added up to approximately 54 microl/min. We believe this is the first demonstration of total retinal blood flow measurement using the OCT technique.

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

July 2007

Volume

12

Issue

4

Start / End Page

041215

Related Subject Headings

  • Tomography, Optical Coherence
  • Sensitivity and Specificity
  • Retinoscopy
  • Retinal Vessels
  • Reproducibility of Results
  • Oximetry
  • Optics
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, Y., Bower, B. A., Izatt, J. A., Tan, O., & Huang, D. (2007). In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography. Journal of Biomedical Optics, 12(4), 041215. https://doi.org/10.1117/1.2772871
Wang, Yimin, Bradley A. Bower, Joseph A. Izatt, Ou Tan, and David Huang. “In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography.Journal of Biomedical Optics 12, no. 4 (July 2007): 041215. https://doi.org/10.1117/1.2772871.
Wang Y, Bower BA, Izatt JA, Tan O, Huang D. In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography. Journal of biomedical optics. 2007 Jul;12(4):041215.
Wang, Yimin, et al. “In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography.Journal of Biomedical Optics, vol. 12, no. 4, July 2007, p. 041215. Epmc, doi:10.1117/1.2772871.
Wang Y, Bower BA, Izatt JA, Tan O, Huang D. In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography. Journal of biomedical optics. 2007 Jul;12(4):041215.

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

July 2007

Volume

12

Issue

4

Start / End Page

041215

Related Subject Headings

  • Tomography, Optical Coherence
  • Sensitivity and Specificity
  • Retinoscopy
  • Retinal Vessels
  • Reproducibility of Results
  • Oximetry
  • Optics
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans