Skip to main content
Journal cover image

Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study.

Publication ,  Journal Article
Naidu, SS; Krucoff, MW; Rutledge, DR; Mao, VW; Zhao, W; Zheng, Q; Wilburn, O; Sudhir, K; Simonton, C; Hermiller, JB
Published in: JACC Cardiovasc Interv
June 2012

OBJECTIVES: The aim of this study was to identify predictors of clinical events after XIENCE V (Abbott Vascular, Santa Clara, California) stenting. BACKGROUND: The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval) study is a prospective, multicenter, Food and Drug Administration-required post-approval study to examine safety and effectiveness in real-world settings. After an initial 5,062 patients, 2,999 more were included as part of the DAPT (Dual Antiplatelet Therapy) trial (total n = 8,061). METHODS: One-year clinical events, including stent thrombosis (ST), cardiac death/myocardial infarction (MI), target lesion failure, and target lesion revascularization, were adjudicated according to Academic Research Consortium criteria, with ST and cardiac death/MI as primary and co-primary endpoints. Demographic, clinical, and procedural variables were assessed by multivariable analysis. A time-dependent covariate assessed the association between DAPT usage and ST. RESULTS: Roughly 61% were off-label; 85.6% remained on DAPT without interruption through 1 year. Incidences of definite/probable ST, cardiac death/MI, target lesion failure, and target lesion revascularization were 0.80% (95% confidence interval [CI]: 0.61% to 1.03%), 7.1% (95% CI: 6.51% to 7.68%), 8.9% (95% CI: 8.30% to 9.60%), and 4.3% (95% CI: 3.82% to 4.75%), respectively. Several independent clinical and angiographic predictors were identified for each outcome. Predictors of ST included DAPT interruption ≤ 30 days (hazard ratio [HR]: 8.63, 95% CI: 2.69 to 27.73, p = 0.0003), renal insufficiency (HR: 3.72, 95% CI: 1.71 to 8.09, p = 0.0009), and total stent length (HR: 1.30, 95% CI: 1.16 to 1.47, p < 0.0001). A DAPT interruption >30 days was not predictive of ST. CONCLUSIONS: In this large, real-world population, XIENCE V demonstrated low event rates at 1 year, with several independent predictors. Early DAPT interruption (≤ 30 days) was the most potent predictor of ST, whereas delayed interruption (>30 days) was not predictive. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520).

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

JACC Cardiovasc Interv

DOI

EISSN

1876-7605

Publication Date

June 2012

Volume

5

Issue

6

Start / End Page

626 / 635

Location

United States

Related Subject Headings

  • United States
  • Treatment Outcome
  • Time Factors
  • Sirolimus
  • Risk Factors
  • Risk Assessment
  • Prosthesis Design
  • Prospective Studies
  • Proportional Hazards Models
  • Platelet Aggregation Inhibitors
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Naidu, S. S., Krucoff, M. W., Rutledge, D. R., Mao, V. W., Zhao, W., Zheng, Q., … Hermiller, J. B. (2012). Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study. JACC Cardiovasc Interv, 5(6), 626–635. https://doi.org/10.1016/j.jcin.2012.02.014
Naidu, Srihari S., Mitchell W. Krucoff, David R. Rutledge, Vivian W. Mao, Weiying Zhao, Qing Zheng, Olivia Wilburn, Krishnankutty Sudhir, Charles Simonton, and James B. Hermiller. “Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study.JACC Cardiovasc Interv 5, no. 6 (June 2012): 626–35. https://doi.org/10.1016/j.jcin.2012.02.014.
Naidu, Srihari S., et al. “Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study.JACC Cardiovasc Interv, vol. 5, no. 6, June 2012, pp. 626–35. Pubmed, doi:10.1016/j.jcin.2012.02.014.
Naidu SS, Krucoff MW, Rutledge DR, Mao VW, Zhao W, Zheng Q, Wilburn O, Sudhir K, Simonton C, Hermiller JB. Contemporary incidence and predictors of stent thrombosis and other major adverse cardiac events in the year after XIENCE V implantation: results from the 8,061-patient XIENCE V United States study. JACC Cardiovasc Interv. 2012 Jun;5(6):626–635.
Journal cover image

Published In

JACC Cardiovasc Interv

DOI

EISSN

1876-7605

Publication Date

June 2012

Volume

5

Issue

6

Start / End Page

626 / 635

Location

United States

Related Subject Headings

  • United States
  • Treatment Outcome
  • Time Factors
  • Sirolimus
  • Risk Factors
  • Risk Assessment
  • Prosthesis Design
  • Prospective Studies
  • Proportional Hazards Models
  • Platelet Aggregation Inhibitors