Skip to main content

Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression.

Publication ,  Journal Article
Kostic, MN; Fakhar, S; Foxall, T; Drakulic, BS; Krucoff, MW
Published in: Annu Int Conf IEEE Eng Med Biol Soc
2007

The performance assessment of a novel ECG signal processing technology in Fidelity 100 (test) and four modern ECG systems (controls) was conducted. A quantitative evaluation for one control and a test system was done by simultaneous recordings on 54 patients undergoing percutaneous coronary intervention (PCI) and on a biological reference signal from an ECG simulator. A qualitative performance of baseline wander suppression was done on all five systems. The results showed that the Fidelity 100 system provided excellent detection and quantification of transient ischemia and baseline wander suppression.

Duke Scholars

Published In

Annu Int Conf IEEE Eng Med Biol Soc

DOI

ISSN

2375-7477

Publication Date

2007

Volume

2007

Start / End Page

2199 / 2202

Location

United States

Related Subject Headings

  • Time Factors
  • Software Design
  • Signal Processing, Computer-Assisted
  • Reproducibility of Results
  • Myocardial Ischemia
  • Ischemic Attack, Transient
  • Humans
  • Equipment Design
  • Electrocardiography
  • Data Interpretation, Statistical
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kostic, M. N., Fakhar, S., Foxall, T., Drakulic, B. S., & Krucoff, M. W. (2007). Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression. Annu Int Conf IEEE Eng Med Biol Soc, 2007, 2199–2202. https://doi.org/10.1109/IEMBS.2007.4352760
Kostic, Marko N., Sina Fakhar, Tom Foxall, Budimir S. Drakulic, and Mitchell W. Krucoff. “Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression.Annu Int Conf IEEE Eng Med Biol Soc 2007 (2007): 2199–2202. https://doi.org/10.1109/IEMBS.2007.4352760.
Kostic MN, Fakhar S, Foxall T, Drakulic BS, Krucoff MW. Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression. Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:2199–202.
Kostic, Marko N., et al. “Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression.Annu Int Conf IEEE Eng Med Biol Soc, vol. 2007, 2007, pp. 2199–202. Pubmed, doi:10.1109/IEMBS.2007.4352760.
Kostic MN, Fakhar S, Foxall T, Drakulic BS, Krucoff MW. Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression. Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:2199–2202.

Published In

Annu Int Conf IEEE Eng Med Biol Soc

DOI

ISSN

2375-7477

Publication Date

2007

Volume

2007

Start / End Page

2199 / 2202

Location

United States

Related Subject Headings

  • Time Factors
  • Software Design
  • Signal Processing, Computer-Assisted
  • Reproducibility of Results
  • Myocardial Ischemia
  • Ischemic Attack, Transient
  • Humans
  • Equipment Design
  • Electrocardiography
  • Data Interpretation, Statistical