Sensors for the CDF Run2b silicon detector
Publication
, Journal Article
Akimoto, T; Aoki, M; Hara, K; Kim, S; Nakamura, Y; Yoshitama, H; Azzi, P; Bacchetta, N; Bisello, D; Busetto, G; Manea, C; Pantano, D; Wang, Z ...
Published in: IEEE Transactions on Nuclear Science
August 1, 2004
We describe the characteristics of silicon microstrip sensors fabricated by Hamamatsu Photonics for the CDF Run 2b silicon detector. A total of 953 sensors, including 117 prototype sensors, have been produced and tested. Five sensors were irradiated with neutrons up to 1.4 × 1014 n/cm2 as a part of the sensor quality assurance program. The electrical and mechanical characteristics are found to be superior in all aspects and fulfill our specifications. We comment on charge-up susceptibility of the sensors that employ a (100) crystal structure.
Duke Scholars
Published In
IEEE Transactions on Nuclear Science
DOI
ISSN
0018-9499
Publication Date
August 1, 2004
Volume
51
Issue
4 I
Start / End Page
1546 / 1554
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0903 Biomedical Engineering
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
Citation
APA
Chicago
ICMJE
MLA
NLM
Akimoto, T., Aoki, M., Hara, K., Kim, S., Nakamura, Y., Yoshitama, H., … Riipinen, P. (2004). Sensors for the CDF Run2b silicon detector. IEEE Transactions on Nuclear Science, 51(4 I), 1546–1554. https://doi.org/10.1109/TNS.2004.832586
Akimoto, T., M. Aoki, K. Hara, S. Kim, Y. Nakamura, H. Yoshitama, P. Azzi, et al. “Sensors for the CDF Run2b silicon detector.” IEEE Transactions on Nuclear Science 51, no. 4 I (August 1, 2004): 1546–54. https://doi.org/10.1109/TNS.2004.832586.
Akimoto T, Aoki M, Hara K, Kim S, Nakamura Y, Yoshitama H, et al. Sensors for the CDF Run2b silicon detector. IEEE Transactions on Nuclear Science. 2004 Aug 1;51(4 I):1546–54.
Akimoto, T., et al. “Sensors for the CDF Run2b silicon detector.” IEEE Transactions on Nuclear Science, vol. 51, no. 4 I, Aug. 2004, pp. 1546–54. Scopus, doi:10.1109/TNS.2004.832586.
Akimoto T, Aoki M, Hara K, Kim S, Nakamura Y, Yoshitama H, Azzi P, Bacchetta N, Bisello D, Busetto G, Manea C, Pantano D, Wang Z, Behari S, Maksimovic P, Nord B, Pursley J, Schuyler B, Benjamin D, Cabrera S, Kruse M, Bolla G, Bortoletto D, Canepa A, Fernandez JP, Novak J, Booth P, Cooke P, Burghard A, Gorelov I, Hoeferkamp M, Naoumov D, Seidel S, Watje P, Cardoso G, Derylo G, Fang I, Flaugher B, Hoff J, Hrycyk M, Lukens P, Merkel P, Moccia S, Nelson T, Orlov Y, Pavlicek V, Shenai A, Wester W, Yarema R, Yun JC, Zimmerman T, Chertok M, Holbrook B, Lander R, Landry T, Pellett D, Soha A, Yao W, Ciobanu CI, Hsiung TH, Junk T, Feng EJ, Freeman J, Galtieri L, Garcia-Sciveres M, Haber C, Krieger B, Lujan PJ, Mandelli E, von der Lippe H, Walder JP, Weber M, Zetti F, Zimmermann S, Galyardt J, Giurgiu G, Hale D, Hill C, Incandela J, Kyre S, Stuart D, Harr R, Hong SC, Jeon EJ, Joo KK, Kong DJ, Lee J, Min SN, Yang YC, Kahkola H, Karjalainen S, Tavi M, Kobayashi K, Nakano I, Tanaka R, Lauhakangas R, Orava R, Osterberg K, Riipinen P. Sensors for the CDF Run2b silicon detector. IEEE Transactions on Nuclear Science. 2004 Aug 1;51(4 I):1546–1554.
Published In
IEEE Transactions on Nuclear Science
DOI
ISSN
0018-9499
Publication Date
August 1, 2004
Volume
51
Issue
4 I
Start / End Page
1546 / 1554
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0903 Biomedical Engineering
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics