Skip to main content
Journal cover image

Arteriovenous fistula creation using the Optiflow vascular anastomosis device: a first in man pilot study.

Publication ,  Journal Article
Manson, RJ; Ebner, A; Gallo, S; Chemla, E; Mantell, M; Deaton, D; Roy-Chaudhury, P
Published in: Seminars in dialysis
January 2013

Although arteriovenous fistulae are the preferred form of dialysis vascular access they continue to have significant problems with maturation failure. The Optiflow device is a sutureless anastomotic conduit which could potentially reduce surgical time and also standardize the surgical procedure. We report herein on the "First in Man" experience with the Optiflow device.

Published In

Seminars in dialysis

DOI

EISSN

1525-139X

ISSN

0894-0959

Publication Date

January 2013

Volume

26

Issue

1

Start / End Page

97 / 99

Related Subject Headings

  • Vascular Patency
  • Vascular Grafting
  • Urology & Nephrology
  • Treatment Outcome
  • Retrospective Studies
  • Renal Dialysis
  • Pilot Projects
  • Male
  • Kidney Failure, Chronic
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Manson, R. J., Ebner, A., Gallo, S., Chemla, E., Mantell, M., Deaton, D., & Roy-Chaudhury, P. (2013). Arteriovenous fistula creation using the Optiflow vascular anastomosis device: a first in man pilot study. Seminars in Dialysis, 26(1), 97–99. https://doi.org/10.1111/j.1525-139x.2012.01062.x
Manson, Roberto J., Adrian Ebner, Santiago Gallo, Eric Chemla, Mark Mantell, David Deaton, and Prabir Roy-Chaudhury. “Arteriovenous fistula creation using the Optiflow vascular anastomosis device: a first in man pilot study.Seminars in Dialysis 26, no. 1 (January 2013): 97–99. https://doi.org/10.1111/j.1525-139x.2012.01062.x.
Manson RJ, Ebner A, Gallo S, Chemla E, Mantell M, Deaton D, et al. Arteriovenous fistula creation using the Optiflow vascular anastomosis device: a first in man pilot study. Seminars in dialysis. 2013 Jan;26(1):97–9.
Manson, Roberto J., et al. “Arteriovenous fistula creation using the Optiflow vascular anastomosis device: a first in man pilot study.Seminars in Dialysis, vol. 26, no. 1, Jan. 2013, pp. 97–99. Epmc, doi:10.1111/j.1525-139x.2012.01062.x.
Manson RJ, Ebner A, Gallo S, Chemla E, Mantell M, Deaton D, Roy-Chaudhury P. Arteriovenous fistula creation using the Optiflow vascular anastomosis device: a first in man pilot study. Seminars in dialysis. 2013 Jan;26(1):97–99.
Journal cover image

Published In

Seminars in dialysis

DOI

EISSN

1525-139X

ISSN

0894-0959

Publication Date

January 2013

Volume

26

Issue

1

Start / End Page

97 / 99

Related Subject Headings

  • Vascular Patency
  • Vascular Grafting
  • Urology & Nephrology
  • Treatment Outcome
  • Retrospective Studies
  • Renal Dialysis
  • Pilot Projects
  • Male
  • Kidney Failure, Chronic
  • Humans