Skip to main content

A new iodinated liver phantom for the quantitative evaluation of advanced CT acquisition and reconstruction techniques

Publication ,  Journal Article
Chen, B; Marin, D; Samei, E
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
May 13, 2011

An iodinated liver phantom is needed for liver CT related studies, such as the quantification of lesion contrast. Prior studies simulated iodinated hepatic lesions with tubes of iodine solution, which involved complications associated with the setup, differences from actual lesion morphology, and susceptibility to iodine sediments. To develop a dedicated liver phantom with anthropomorphic structures and solid lesions, we designed a phantom with iodinated liver inserts and lesions of different sizes and contrasts. The concentration of iodine in liver parenchyma was determined according to the HU measured from clinical images. The concentrations in high and low contrast lesions were selected so as to provide challenging but reasonable detection tasks. The application of the liver phantom was initially validated at different doses and reconstruction settings. © 2011 SPIE.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

May 13, 2011

Volume

7961
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chen, B., Marin, D., & Samei, E. (2011). A new iodinated liver phantom for the quantitative evaluation of advanced CT acquisition and reconstruction techniques. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 7961. https://doi.org/10.1117/12.878916
Chen, B., D. Marin, and E. Samei. “A new iodinated liver phantom for the quantitative evaluation of advanced CT acquisition and reconstruction techniques.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 7961 (May 13, 2011). https://doi.org/10.1117/12.878916.
Chen B, Marin D, Samei E. A new iodinated liver phantom for the quantitative evaluation of advanced CT acquisition and reconstruction techniques. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2011 May 13;7961.
Chen, B., et al. “A new iodinated liver phantom for the quantitative evaluation of advanced CT acquisition and reconstruction techniques.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 7961, May 2011. Scopus, doi:10.1117/12.878916.
Chen B, Marin D, Samei E. A new iodinated liver phantom for the quantitative evaluation of advanced CT acquisition and reconstruction techniques. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2011 May 13;7961.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

May 13, 2011

Volume

7961