Skip to main content

Capillary zone electrophoresis-mass spectrometry using a coaxial continuous-flow fast atom bombardment interface.

Publication ,  Journal Article
Moseley, MA; Deterding, LJ; Tomer, KB; Jorgenson, JW
Published in: J Chromatogr
September 7, 1990

Mixtures of peptides have been analyzed by capillary zone electrophoresis in conjunction with mass spectrometry (MS) using an on-line coaxial continuous-flow fast atom bombardment interface. MS and MS-MS spectra have been acquired in electrophoretic real time from femtomole levels of the peptides, while maintaining separation efficiencies in excess of 100,000 theoretical plates.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Chromatogr

DOI

Publication Date

September 7, 1990

Volume

516

Issue

1

Start / End Page

167 / 173

Location

Netherlands

Related Subject Headings

  • Spectrometry, Mass, Fast Atom Bombardment
  • Oligopeptides
  • Neuropeptides
  • N-Formylmethionine Leucyl-Phenylalanine
  • Molecular Structure
  • Endorphins
  • Electrophoresis
  • Chemotactic Factors
  • Analytical Chemistry
  • Analgesics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Moseley, M. A., Deterding, L. J., Tomer, K. B., & Jorgenson, J. W. (1990). Capillary zone electrophoresis-mass spectrometry using a coaxial continuous-flow fast atom bombardment interface. J Chromatogr, 516(1), 167–173. https://doi.org/10.1016/s0021-9673(01)90214-6
Moseley, M. A., L. J. Deterding, K. B. Tomer, and J. W. Jorgenson. “Capillary zone electrophoresis-mass spectrometry using a coaxial continuous-flow fast atom bombardment interface.J Chromatogr 516, no. 1 (September 7, 1990): 167–73. https://doi.org/10.1016/s0021-9673(01)90214-6.
Moseley MA, Deterding LJ, Tomer KB, Jorgenson JW. Capillary zone electrophoresis-mass spectrometry using a coaxial continuous-flow fast atom bombardment interface. J Chromatogr. 1990 Sep 7;516(1):167–73.
Moseley, M. A., et al. “Capillary zone electrophoresis-mass spectrometry using a coaxial continuous-flow fast atom bombardment interface.J Chromatogr, vol. 516, no. 1, Sept. 1990, pp. 167–73. Pubmed, doi:10.1016/s0021-9673(01)90214-6.
Moseley MA, Deterding LJ, Tomer KB, Jorgenson JW. Capillary zone electrophoresis-mass spectrometry using a coaxial continuous-flow fast atom bombardment interface. J Chromatogr. 1990 Sep 7;516(1):167–173.

Published In

J Chromatogr

DOI

Publication Date

September 7, 1990

Volume

516

Issue

1

Start / End Page

167 / 173

Location

Netherlands

Related Subject Headings

  • Spectrometry, Mass, Fast Atom Bombardment
  • Oligopeptides
  • Neuropeptides
  • N-Formylmethionine Leucyl-Phenylalanine
  • Molecular Structure
  • Endorphins
  • Electrophoresis
  • Chemotactic Factors
  • Analytical Chemistry