Skip to main content
Journal cover image

Response of brain tissue to chronically implanted neural electrodes.

Publication ,  Journal Article
Polikov, VS; Tresco, PA; Reichert, WM
Published in: Journal of neuroscience methods
October 2005

Chronically implanted recording electrode arrays linked to prosthetics have the potential to make positive impacts on patients suffering from full or partial paralysis. Such arrays are implanted into the patient's cortical tissue and record extracellular potentials from nearby neurons, allowing the information encoded by the neuronal discharges to control external devices. While such systems perform well during acute recordings, they often fail to function reliably in clinically relevant chronic settings. Available evidence suggests that a major failure mode of electrode arrays is the brain tissue reaction against these implants, making the biocompatibility of implanted electrodes a primary concern in device design. This review presents the biological components and time course of the acute and chronic tissue reaction in brain tissue, analyses the brain tissue response of current electrode systems, and comments on the various material science and bioactive strategies undertaken by electrode designers to enhance electrode performance.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of neuroscience methods

DOI

EISSN

1872-678X

ISSN

0165-0270

Publication Date

October 2005

Volume

148

Issue

1

Start / End Page

1 / 18

Related Subject Headings

  • Tumor Necrosis Factors
  • Phosphopyruvate Hydratase
  • Neurons
  • Neurology & Neurosurgery
  • Neuroglia
  • Neurofilament Proteins
  • Membrane Proteins
  • Inflammation
  • Humans
  • Glial Fibrillary Acidic Protein
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005). Response of brain tissue to chronically implanted neural electrodes. Journal of Neuroscience Methods, 148(1), 1–18. https://doi.org/10.1016/j.jneumeth.2005.08.015
Polikov, Vadim S., Patrick A. Tresco, and William M. Reichert. “Response of brain tissue to chronically implanted neural electrodes.Journal of Neuroscience Methods 148, no. 1 (October 2005): 1–18. https://doi.org/10.1016/j.jneumeth.2005.08.015.
Polikov VS, Tresco PA, Reichert WM. Response of brain tissue to chronically implanted neural electrodes. Journal of neuroscience methods. 2005 Oct;148(1):1–18.
Polikov, Vadim S., et al. “Response of brain tissue to chronically implanted neural electrodes.Journal of Neuroscience Methods, vol. 148, no. 1, Oct. 2005, pp. 1–18. Epmc, doi:10.1016/j.jneumeth.2005.08.015.
Polikov VS, Tresco PA, Reichert WM. Response of brain tissue to chronically implanted neural electrodes. Journal of neuroscience methods. 2005 Oct;148(1):1–18.
Journal cover image

Published In

Journal of neuroscience methods

DOI

EISSN

1872-678X

ISSN

0165-0270

Publication Date

October 2005

Volume

148

Issue

1

Start / End Page

1 / 18

Related Subject Headings

  • Tumor Necrosis Factors
  • Phosphopyruvate Hydratase
  • Neurons
  • Neurology & Neurosurgery
  • Neuroglia
  • Neurofilament Proteins
  • Membrane Proteins
  • Inflammation
  • Humans
  • Glial Fibrillary Acidic Protein