Comparison of dual-window scatter correction and effective attenuation coefficients for quantification in dedicated breast SPECT

Publication ,  Journal Article
Mann, S; Perez, K; Tornai, M
Published in: IEEE Nuclear Science Symposium Conference Record
January 1, 2011

Correction for scattered and attenuated photons is necessary for accurate quantification in dedicated breast SPECT. An implemented dual energy window (DEW) scatter correction method along with attenuation correction has been shown to be accurate to within 10% of true values; however, the DEW method requires multiple processing steps, and thus more time, than an effective attenuation coefficient (EAC) method. This study aims to determine an EAC for quantification accuracy comparable to the DEW method. Our dedicated, high performance CZT-based breast SPECT system is capable of novel 3D, non-traditional trajectories. A breast phantom containing lesions ranging from 0.1 to 1.6mL was filled with Tc-99m to 8:1 and 4:1 lesion-to-background activity concentrations. Multiple acquisitions were collected using vertical axis of rotation (VAOR) and projected sine wave (PROJSINE) orbits and an 8% energy window. The PROJSINE trajectory incompletely samples the volume, but offers potential clinical benefits by contouring the breast and acquiring chest wall projections. Images were reconstructed with OSEM to 20 iterations using both uniform EAC masks with values of 0.12 to 0.165cm-1 and the DEW method with measured 0.16 scatter coefficient and the NIST attenuation value of 0.1545cm-1 for water at 140keV. ROIs were seeded and automatically drawn within each lesion, and measured values were compared to known truth. Results indicate that the DEW method is superior for VAOR trajectories and a single EAC value may not adequately compensate non-uniformly shaped objects that have a spatially varying scatter distribution. However, for PROJSINE trajectories, an EAC of approximately 0.13cm-1 yields comparable quantification accuracy for background and large lesions without the need for additional image processing, indicating this may have clinical utility in image quantification. © 2011 IEEE.

Duke Scholars

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

January 1, 2011

Start / End Page

3760 / 3763
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mann, S., Perez, K., & Tornai, M. (2011). Comparison of dual-window scatter correction and effective attenuation coefficients for quantification in dedicated breast SPECT. IEEE Nuclear Science Symposium Conference Record, 3760–3763. https://doi.org/10.1109/NSSMIC.2011.6153711
Mann, S., K. Perez, and M. Tornai. “Comparison of dual-window scatter correction and effective attenuation coefficients for quantification in dedicated breast SPECT.” IEEE Nuclear Science Symposium Conference Record, January 1, 2011, 3760–63. https://doi.org/10.1109/NSSMIC.2011.6153711.
Mann S, Perez K, Tornai M. Comparison of dual-window scatter correction and effective attenuation coefficients for quantification in dedicated breast SPECT. IEEE Nuclear Science Symposium Conference Record. 2011 Jan 1;3760–3.
Mann, S., et al. “Comparison of dual-window scatter correction and effective attenuation coefficients for quantification in dedicated breast SPECT.” IEEE Nuclear Science Symposium Conference Record, Jan. 2011, pp. 3760–63. Scopus, doi:10.1109/NSSMIC.2011.6153711.
Mann S, Perez K, Tornai M. Comparison of dual-window scatter correction and effective attenuation coefficients for quantification in dedicated breast SPECT. IEEE Nuclear Science Symposium Conference Record. 2011 Jan 1;3760–3763.

Published In

IEEE Nuclear Science Symposium Conference Record

DOI

ISSN

1095-7863

Publication Date

January 1, 2011

Start / End Page

3760 / 3763