The goal of this study was to characterize the image quality of our dedicated, quasi-monochromatic spectrum, cone beam breast imaging system under scatter corrected and non-scatter corrected conditions for a variety of breast compositions. CT projections were acquired of a breast phantom containing two concentric sets of acrylic spheres that varied in size (1-8mm) based on their polar position. The breast phantom was filled with 3 different concentrations of methanol and water, simulating a range of breast densities (0.79-1.0g/cc); acrylic yarn was sometimes included to simulate connective tissue of a breast. For each phantom condition, 2D scatter was measured for all projection angles. Scatter-corrected and uncorrected projections were then reconstructed with an iterative ordered subsets convex algorithm. Reconstructed image quality was characterized using SNR and contrast analysis, and followed by a human observer detection task for the spheres in the different concentric rings. Results show that scatter correction effectively reduces the cupping artifact and improves image contrast and SNR. Results from the observer study indicate that there was no statistical difference in the number or sizes of lesions observed in the scatter versus non-scatter corrected images for all densities. Nonetheless, applying scatter correction for differing breast conditions improves overall image quality.

Duke Scholars

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

March 16, 2011

Volume

7961

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pachon, J. H., Shah, J., & Tornai, M. P. (2011). Characterization of Image Quality for 3D Scatter Corrected Breast CT Images. Proc SPIE Int Soc Opt Eng, 7961. https://doi.org/10.1117/12.878808
Pachon, Jan H., Jainil Shah, and Martin P. Tornai. “Characterization of Image Quality for 3D Scatter Corrected Breast CT Images.Proc SPIE Int Soc Opt Eng 7961 (March 16, 2011). https://doi.org/10.1117/12.878808.
Pachon JH, Shah J, Tornai MP. Characterization of Image Quality for 3D Scatter Corrected Breast CT Images. Proc SPIE Int Soc Opt Eng. 2011 Mar 16;7961.
Pachon, Jan H., et al. “Characterization of Image Quality for 3D Scatter Corrected Breast CT Images.Proc SPIE Int Soc Opt Eng, vol. 7961, Mar. 2011. Pubmed, doi:10.1117/12.878808.
Pachon JH, Shah J, Tornai MP. Characterization of Image Quality for 3D Scatter Corrected Breast CT Images. Proc SPIE Int Soc Opt Eng. 2011 Mar 16;7961.

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

March 16, 2011

Volume

7961

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering