Skip to main content

Feasability of a ARFI/B-mode/Doppler system for real-time, freehand scanning of the cardiovascular system

Publication ,  Journal Article
Dumont, DM; Lee, SY; Doherty, JR; Trahey, GE
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
June 8, 2011

Acoustic radiation force impulse (ARFI) imaging has been previously described for the visualization of the cardiovascular system, including assessment of cerebral and lower-limb vascular disease, myocardial function, and cardiac RF ablation monitoring. Given that plaque imposes a 3-dimensional burden on the artery and that accurate visualization of all lesion borders are important for ablation guidance, it would be convenient if an entire plaque or lesion volume could be acquired, either using a 3D system or 2D freehand scanning. Currently, ARFI imaging uses single-frame acquisition, with acquisition times ranging from 100-200ms. Such a system would be cumbersome for real-time, freehand scanning. In this work, we evaluate the feasibility of using ARFI for freehand, real-time scanning of the cardiovascular system. New techniques are presented which acquire B-mode / ARFI/ and Color-flow Doppler (BACD) information in less than 50 ms. Freehand feasibility is evaluated by sweeping the BACD system across lesion phantoms and vascular phantoms modeling a thin-cap fibroatheroma at sweep rates currently utilized in conventional B-mode systems. Stationary in vivo BACD images were then formed from the carotid artery of a canine model, demonstrating the system's potential. The results suggest that little loss in either ARFI or Doppler quality occurs during translational-stage controlled, quasi-freehand sweeps. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 8, 2011

Volume

7968
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dumont, D. M., Lee, S. Y., Doherty, J. R., & Trahey, G. E. (2011). Feasability of a ARFI/B-mode/Doppler system for real-time, freehand scanning of the cardiovascular system. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 7968. https://doi.org/10.1117/12.877841
Dumont, D. M., S. Y. Lee, J. R. Doherty, and G. E. Trahey. “Feasability of a ARFI/B-mode/Doppler system for real-time, freehand scanning of the cardiovascular system.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 7968 (June 8, 2011). https://doi.org/10.1117/12.877841.
Dumont DM, Lee SY, Doherty JR, Trahey GE. Feasability of a ARFI/B-mode/Doppler system for real-time, freehand scanning of the cardiovascular system. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2011 Jun 8;7968.
Dumont, D. M., et al. “Feasability of a ARFI/B-mode/Doppler system for real-time, freehand scanning of the cardiovascular system.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 7968, June 2011. Scopus, doi:10.1117/12.877841.
Dumont DM, Lee SY, Doherty JR, Trahey GE. Feasability of a ARFI/B-mode/Doppler system for real-time, freehand scanning of the cardiovascular system. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2011 Jun 8;7968.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 8, 2011

Volume

7968