Skip to main content

3-D motion tracking using raw data and a matrix array: Phantom and in vivo cardiac studies

Publication ,  Journal Article
Byram, BC; Holley, G; Need, D; Giannantonio, DM; Trahey, GE
Published in: Proceedings - IEEE Ultrasonics Symposium
January 1, 2009

Three dimensional ultrasound motion tracking has been previously demonstrated using detected data at low volume rates. However, the effects of volume rate, kernel size and data type (raw and detected) have not been sufficiently explored. First comparisons are made within the stated variables for 3-D speckle tracking. Volumetric data were obtained in a raw, baseband format using a matrix array attached to a high parallel receive beam count scanner. The scanner was used to acquire phantom and human in vivo cardiac volumetric data at 1000 Hz volume rates. Motion was tracked using phase-sensitive normalized cross-correlation. Subsample estimation in the lateral and elevational dimensions used the grid-slopes algorithm. The effects of frame rate, kernel size and data type on 3-D tracking are shown. In general, the results show improvement of motion estimates at volume rates up to 200 Hz, above which they become stable. However, peak and pixel hopping continue to decrease at volume rates higher than 200 Hz. The tracking method and data show, qualitatively, good temporal and spatial stability (for independent kernels) at high volume rates. ©2009 IEEE.

Duke Scholars

Published In

Proceedings - IEEE Ultrasonics Symposium

DOI

ISSN

1051-0117

Publication Date

January 1, 2009

Start / End Page

502 / 506
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Byram, B. C., Holley, G., Need, D., Giannantonio, D. M., & Trahey, G. E. (2009). 3-D motion tracking using raw data and a matrix array: Phantom and in vivo cardiac studies. Proceedings - IEEE Ultrasonics Symposium, 502–506. https://doi.org/10.1109/ULTSYM.2009.5441868
Byram, B. C., G. Holley, D. Need, D. M. Giannantonio, and G. E. Trahey. “3-D motion tracking using raw data and a matrix array: Phantom and in vivo cardiac studies.” Proceedings - IEEE Ultrasonics Symposium, January 1, 2009, 502–6. https://doi.org/10.1109/ULTSYM.2009.5441868.
Byram BC, Holley G, Need D, Giannantonio DM, Trahey GE. 3-D motion tracking using raw data and a matrix array: Phantom and in vivo cardiac studies. Proceedings - IEEE Ultrasonics Symposium. 2009 Jan 1;502–6.
Byram, B. C., et al. “3-D motion tracking using raw data and a matrix array: Phantom and in vivo cardiac studies.” Proceedings - IEEE Ultrasonics Symposium, Jan. 2009, pp. 502–06. Scopus, doi:10.1109/ULTSYM.2009.5441868.
Byram BC, Holley G, Need D, Giannantonio DM, Trahey GE. 3-D motion tracking using raw data and a matrix array: Phantom and in vivo cardiac studies. Proceedings - IEEE Ultrasonics Symposium. 2009 Jan 1;502–506.

Published In

Proceedings - IEEE Ultrasonics Symposium

DOI

ISSN

1051-0117

Publication Date

January 1, 2009

Start / End Page

502 / 506