Skip to main content

A simulation study of a bedside cardiac PET imager

Publication ,  Journal Article
Tipnis, UJ; Smith, MF; Turkington, TG; Wilson, J; Majewski, S; Kross, B; Wojcik, R; Gilland, DR
Published in: IEEE Nuclear Science Symposium Conference Record
December 1, 2004

This paper presents the results of a simulation study on the imaging performance of a bedside cardiac PET system. The proposed system consists of two compact gamma cameras mounted on a mobile gantry. Key challenges presented by this imaging context include: detector positioning to obtain sufficient angular sampling, attenuation correction in the absence of transmission images, and control of image noise. The primary aim of this paper was to quantify the extent of reconstructed image artifacts that result from these effects under the anticipated imaging conditions. The simulation studies demonstrated that limited angle acquisition is the primary source of artifacts followed by attenuation effects. Image noise in this context was not a major factor in the reconstructed image quality. Image artifacts resulting in a nearly 50% variation in image intensity in isolated regions of the myocardium could be expected from this imaging system. Such artifacts render the detection of mild myocardial defects highly difficult; however, severe defects should still be detectable with this system, which can offer important diagnostic information for this patient population. © 2004 IEEE.

Duke Scholars

Published In

IEEE Nuclear Science Symposium Conference Record

ISSN

1095-7863

Publication Date

December 1, 2004

Volume

5

Start / End Page

3126 / 3129
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tipnis, U. J., Smith, M. F., Turkington, T. G., Wilson, J., Majewski, S., Kross, B., … Gilland, D. R. (2004). A simulation study of a bedside cardiac PET imager. IEEE Nuclear Science Symposium Conference Record, 5, 3126–3129.
Tipnis, U. J., M. F. Smith, T. G. Turkington, J. Wilson, S. Majewski, B. Kross, R. Wojcik, and D. R. Gilland. “A simulation study of a bedside cardiac PET imager.” IEEE Nuclear Science Symposium Conference Record 5 (December 1, 2004): 3126–29.
Tipnis UJ, Smith MF, Turkington TG, Wilson J, Majewski S, Kross B, et al. A simulation study of a bedside cardiac PET imager. IEEE Nuclear Science Symposium Conference Record. 2004 Dec 1;5:3126–9.
Tipnis, U. J., et al. “A simulation study of a bedside cardiac PET imager.” IEEE Nuclear Science Symposium Conference Record, vol. 5, Dec. 2004, pp. 3126–29.
Tipnis UJ, Smith MF, Turkington TG, Wilson J, Majewski S, Kross B, Wojcik R, Gilland DR. A simulation study of a bedside cardiac PET imager. IEEE Nuclear Science Symposium Conference Record. 2004 Dec 1;5:3126–3129.

Published In

IEEE Nuclear Science Symposium Conference Record

ISSN

1095-7863

Publication Date

December 1, 2004

Volume

5

Start / End Page

3126 / 3129