Construction and evaluation of a regenerable fluoroimmunochemical-based fibre optic biosensor

Publication ,  Journal Article
Bowyer, JR; Alarie, JP; Sepaniak, MJ; Vo-Dinh, T; Thompson, RQ
Published in: The Analyst
December 1, 1991

A microscale fibre optic biosensor that is capable of in situ regeneration is described and characterized. By combining recently developed fibre optic sensing technology with a capillary column reagent delivery system, it is possible to perform a variety of bench-top affinity assay procedures both repetitively and remotely. The configuration of the sensing chamber at the terminus of the fibre is an important design feature. The construction and operation of the sensor is described and the results of evaluations of the sensor using an antibody-antigen system are presented. Affinity assay steps such as the delivery of solid phase affinity reagents, secondary reagents and rinse solutions are demonstrated. Sampling is accomplished by mild aspiration. Relative standard deviations (RSDs) for these steps are all less than 10%. The capability of selectively measuring fluorescently labelled anti-rabbit immunoglobulin G (lgG), in the presence of a similar protein, by utilizing its immunospecific interaction with rabbit lgG immobilized on silica beads is demonstrated, and exhibits an RSD of 6.2%. A near linear calibration graph is presented over a concentration range of between 0.011 (approximately the limit of detection) and 0.11 mg ml-1.

Duke Scholars

Published In

The Analyst

DOI

ISSN

0003-2654

Publication Date

December 1, 1991

Volume

116

Issue

2

Start / End Page

117 / 122

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0399 Other Chemical Sciences
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bowyer, J. R., Alarie, J. P., Sepaniak, M. J., Vo-Dinh, T., & Thompson, R. Q. (1991). Construction and evaluation of a regenerable fluoroimmunochemical-based fibre optic biosensor. The Analyst, 116(2), 117–122. https://doi.org/10.1039/AN9911600117
Bowyer, J. R., J. P. Alarie, M. J. Sepaniak, T. Vo-Dinh, and R. Q. Thompson. “Construction and evaluation of a regenerable fluoroimmunochemical-based fibre optic biosensor.” The Analyst 116, no. 2 (December 1, 1991): 117–22. https://doi.org/10.1039/AN9911600117.
Bowyer JR, Alarie JP, Sepaniak MJ, Vo-Dinh T, Thompson RQ. Construction and evaluation of a regenerable fluoroimmunochemical-based fibre optic biosensor. The Analyst. 1991 Dec 1;116(2):117–22.
Bowyer, J. R., et al. “Construction and evaluation of a regenerable fluoroimmunochemical-based fibre optic biosensor.” The Analyst, vol. 116, no. 2, Dec. 1991, pp. 117–22. Scopus, doi:10.1039/AN9911600117.
Bowyer JR, Alarie JP, Sepaniak MJ, Vo-Dinh T, Thompson RQ. Construction and evaluation of a regenerable fluoroimmunochemical-based fibre optic biosensor. The Analyst. 1991 Dec 1;116(2):117–122.
Journal cover image

Published In

The Analyst

DOI

ISSN

0003-2654

Publication Date

December 1, 1991

Volume

116

Issue

2

Start / End Page

117 / 122

Related Subject Headings

  • Analytical Chemistry
  • 3401 Analytical chemistry
  • 0399 Other Chemical Sciences
  • 0301 Analytical Chemistry