Fluorescence monitoring of a benzo[a]pyrene metabolite using a regenerable immunochemical-based fiber-optic sensor
Publication
, Journal Article
Alarie, JP; Bowyer, JR; Sepaniak, MJ; Hoyt, AM; Vo-dinh, T
Published in: Analytica Chimica Acta
January 1, 1990
Microscale regenerable biosensors are described and utilized to measure the natural fluorophor benzo[a]pyrene tetraol (BPT). The sensors combine laser-excited/fiber-optic remote sensing principles with a unique capillary tube delivery system to make repetitive, heterogeneous fluoroimmunoassay measurements. Two sensor configurations and modes of operation are described. Concentrations of BPT in the nanomolar range are easily measured with a reproducibility of 10% or better, depending on the sensor design, selective measurements can be made in ca. 20 min, then the sensor can be regenerated by delivering new reagents to the sensing chamber, without removing the sensor from the sample. © 1990.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Analytica Chimica Acta
DOI
ISSN
0003-2670
Publication Date
January 1, 1990
Volume
236
Issue
C
Start / End Page
237 / 244
Related Subject Headings
- Analytical Chemistry
- 4018 Nanotechnology
- 4004 Chemical engineering
- 3401 Analytical chemistry
- 0399 Other Chemical Sciences
- 0301 Analytical Chemistry
Citation
APA
Chicago
ICMJE
MLA
NLM
Alarie, J. P., Bowyer, J. R., Sepaniak, M. J., Hoyt, A. M., & Vo-dinh, T. (1990). Fluorescence monitoring of a benzo[a]pyrene metabolite using a regenerable immunochemical-based fiber-optic sensor. Analytica Chimica Acta, 236(C), 237–244. https://doi.org/10.1016/S0003-2670(00)83317-6
Alarie, J. P., J. R. Bowyer, M. J. Sepaniak, A. M. Hoyt, and T. Vo-dinh. “Fluorescence monitoring of a benzo[a]pyrene metabolite using a regenerable immunochemical-based fiber-optic sensor.” Analytica Chimica Acta 236, no. C (January 1, 1990): 237–44. https://doi.org/10.1016/S0003-2670(00)83317-6.
Alarie JP, Bowyer JR, Sepaniak MJ, Hoyt AM, Vo-dinh T. Fluorescence monitoring of a benzo[a]pyrene metabolite using a regenerable immunochemical-based fiber-optic sensor. Analytica Chimica Acta. 1990 Jan 1;236(C):237–44.
Alarie, J. P., et al. “Fluorescence monitoring of a benzo[a]pyrene metabolite using a regenerable immunochemical-based fiber-optic sensor.” Analytica Chimica Acta, vol. 236, no. C, Jan. 1990, pp. 237–44. Scopus, doi:10.1016/S0003-2670(00)83317-6.
Alarie JP, Bowyer JR, Sepaniak MJ, Hoyt AM, Vo-dinh T. Fluorescence monitoring of a benzo[a]pyrene metabolite using a regenerable immunochemical-based fiber-optic sensor. Analytica Chimica Acta. 1990 Jan 1;236(C):237–244.
Published In
Analytica Chimica Acta
DOI
ISSN
0003-2670
Publication Date
January 1, 1990
Volume
236
Issue
C
Start / End Page
237 / 244
Related Subject Headings
- Analytical Chemistry
- 4018 Nanotechnology
- 4004 Chemical engineering
- 3401 Analytical chemistry
- 0399 Other Chemical Sciences
- 0301 Analytical Chemistry