C-mode real-time tomographic reflection for a matrix array ultrasound sonic flashlight.

Publication ,  Journal Article
Stetten, G; Cois, A; Chang, W; Shelton, D; Tamburo, R; Castellucci, J; von Ramm, O
Published in: Academic radiology
May 2005

Real-time tomographic reflection (RTTR) permits in situ visualization of tomographic images so that natural hand-eye coordination can be used directly during invasive procedures. The method uses a half-silvered mirror to merge the visual outer surface of the patient with a simultaneous scan of the patient's interior without requiring a head-mounted display or tracking. A viewpoint-independent virtual image is reflected precisely into its actual location. When applied to ultrasound, we call the resulting RTTR device the sonic flashlight. We previously implemented the sonic flashlight using conventional two-dimensional ultrasound scanners that produce B-mode slices. Real-time three-dimensional (RT3D) ultrasound scanners recently have been developed that permit RTTR to be applied to slices with other orientations, including C-mode (parallel to the face of the transducer). Such slice orientation may offer advantages for image-guided intervention.Using a prototype scanner developed at Duke University (Durham, NC) with a matrix array that electronically steers an ultrasound beam at high speed in 3D, we implemented a sonic flashlight capable of displaying C-mode images in situ in real time.We present the first images from the C-mode sonic flashlight, showing bones in the hand and the cardiac ventricles.The extension of RTTR to matrix array RT3D ultrasound offers the ability to visualize in situ slices other than the conventional B-mode slice, including C-mode slices parallel to the face of the transducer. This orientation may provide a broader target, facilitating certain interventional procedures. Future work is discussed, including display of slices with arbitrary orientation and use of a holographic optical element instead of a mirror.

Duke Scholars

Published In

Academic radiology

DOI

EISSN

1878-4046

ISSN

1076-6332

Publication Date

May 2005

Volume

12

Issue

5

Start / End Page

535 / 543

Related Subject Headings

  • Ultrasonography
  • Nuclear Medicine & Medical Imaging
  • Imaging, Three-Dimensional
  • Image Processing, Computer-Assisted
  • Image Enhancement
  • Humans
  • Equipment Design
  • Data Display
  • Calibration
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Stetten, G., Cois, A., Chang, W., Shelton, D., Tamburo, R., Castellucci, J., & von Ramm, O. (2005). C-mode real-time tomographic reflection for a matrix array ultrasound sonic flashlight. Academic Radiology, 12(5), 535–543. https://doi.org/10.1016/j.acra.2004.06.011
Stetten, George, Aaron Cois, Wilson Chang, Damion Shelton, Robert Tamburo, John Castellucci, and Olaf von Ramm. “C-mode real-time tomographic reflection for a matrix array ultrasound sonic flashlight.Academic Radiology 12, no. 5 (May 2005): 535–43. https://doi.org/10.1016/j.acra.2004.06.011.
Stetten G, Cois A, Chang W, Shelton D, Tamburo R, Castellucci J, et al. C-mode real-time tomographic reflection for a matrix array ultrasound sonic flashlight. Academic radiology. 2005 May;12(5):535–43.
Stetten, George, et al. “C-mode real-time tomographic reflection for a matrix array ultrasound sonic flashlight.Academic Radiology, vol. 12, no. 5, May 2005, pp. 535–43. Epmc, doi:10.1016/j.acra.2004.06.011.
Stetten G, Cois A, Chang W, Shelton D, Tamburo R, Castellucci J, von Ramm O. C-mode real-time tomographic reflection for a matrix array ultrasound sonic flashlight. Academic radiology. 2005 May;12(5):535–543.
Journal cover image

Published In

Academic radiology

DOI

EISSN

1878-4046

ISSN

1076-6332

Publication Date

May 2005

Volume

12

Issue

5

Start / End Page

535 / 543

Related Subject Headings

  • Ultrasonography
  • Nuclear Medicine & Medical Imaging
  • Imaging, Three-Dimensional
  • Image Processing, Computer-Assisted
  • Image Enhancement
  • Humans
  • Equipment Design
  • Data Display
  • Calibration
  • 3202 Clinical sciences