Skip to main content
Journal cover image

Abdominal and obstetric applications of a dynamically focused phased array real time ultrasound system.

Publication ,  Journal Article
Morgan, CL; Trought, WS; von Ramm, OT; Thurstone, FL
Published in: Clinical radiology
May 1980

Abdominal and obstetric applications of a dynamically focused phased array real time ultrasonic system are described. This work was performed utilising both the Thaumascan (two-dimensional, high resolution, actual time, ultrasound, multi-element array scanner) and the first commercial unit based on this system, the Grumman RT-400. Examples of normal and pathological anatomy are presented from over 300 examinations performed to date, including a series of 28 abdominal aortic aneurysms studied with the RT-400. Following electronic alterations in the Thaumascan with resultant improvement in the grey scale, prospective analyses in 86 obstetric and 23 abdominal examinations were undertaken. These studies indicate that fetal, intra-uterine, and abdominal structures can be rapidly and consistently imaged. The value of real time ultrasonic scanning in obstetric and abdominal examinations is illustrated. The principles of dynamically focused phased arrays are described, and the merits and limitations of these systems are discussed.

Duke Scholars

Published In

Clinical radiology

DOI

EISSN

1365-229X

ISSN

0009-9260

Publication Date

May 1980

Volume

31

Issue

3

Start / End Page

277 / 286

Related Subject Headings

  • Umbilical Cord
  • Ultrasonography
  • Ultrasonics
  • Pregnancy
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Fetus
  • Fetal Diseases
  • Female
  • Biliary Tract
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Morgan, C. L., Trought, W. S., von Ramm, O. T., & Thurstone, F. L. (1980). Abdominal and obstetric applications of a dynamically focused phased array real time ultrasound system. Clinical Radiology, 31(3), 277–286. https://doi.org/10.1016/s0009-9260(80)80217-0
Morgan, C. L., W. S. Trought, O. T. von Ramm, and F. L. Thurstone. “Abdominal and obstetric applications of a dynamically focused phased array real time ultrasound system.Clinical Radiology 31, no. 3 (May 1980): 277–86. https://doi.org/10.1016/s0009-9260(80)80217-0.
Morgan CL, Trought WS, von Ramm OT, Thurstone FL. Abdominal and obstetric applications of a dynamically focused phased array real time ultrasound system. Clinical radiology. 1980 May;31(3):277–86.
Morgan, C. L., et al. “Abdominal and obstetric applications of a dynamically focused phased array real time ultrasound system.Clinical Radiology, vol. 31, no. 3, May 1980, pp. 277–86. Epmc, doi:10.1016/s0009-9260(80)80217-0.
Morgan CL, Trought WS, von Ramm OT, Thurstone FL. Abdominal and obstetric applications of a dynamically focused phased array real time ultrasound system. Clinical radiology. 1980 May;31(3):277–286.
Journal cover image

Published In

Clinical radiology

DOI

EISSN

1365-229X

ISSN

0009-9260

Publication Date

May 1980

Volume

31

Issue

3

Start / End Page

277 / 286

Related Subject Headings

  • Umbilical Cord
  • Ultrasonography
  • Ultrasonics
  • Pregnancy
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Fetus
  • Fetal Diseases
  • Female
  • Biliary Tract