The use of dual-mobility components in total hip arthroplasty.

Publication ,  Journal Article
Lachiewicz, PF; Watters, TS
Published in: J Am Acad Orthop Surg
August 2012

Dual-mobility hip components provide for an additional articular surface, with the goal of improving range of motion, jump distance (ie, vertical or inferior head displacement required for dislocation), and stability of the total hip arthroplasty. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal head is snap-fit within the polyethylene. New components have recently been released for use in North America. Although these devices are routinely used in some European centers for primary hip arthroplasty, their greatest utility may be to manage recurrent dislocation in the setting of revision hip arthroplasty. Several small retrospective series have shown satisfactory results for this indication at short- to midterm follow-up. Polyethylene wear and intraprosthetic dislocation are concerns, as is the lack of long-term data. Caution is thus advised in the routine use of dual-mobility components in primary and revision total hip arthroplasty.

Duke Scholars

Published In

J Am Acad Orthop Surg

DOI

ISSN

1067-151X

Publication Date

August 2012

Volume

20

Issue

8

Start / End Page

481 / 486

Location

United States

Related Subject Headings

  • Reoperation
  • Recurrence
  • Prosthesis Failure
  • Prosthesis Design
  • Polyethylenes
  • Osteoarthritis, Hip
  • Orthopedics
  • Joint Instability
  • Joint Dislocations
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lachiewicz, P. F., & Watters, T. S. (2012). The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg, 20(8), 481–486. https://doi.org/10.5435/JAAOS-20-08-481
Lachiewicz, Paul F., and Tyler Steven Watters. “The use of dual-mobility components in total hip arthroplasty.J Am Acad Orthop Surg 20, no. 8 (August 2012): 481–86. https://doi.org/10.5435/JAAOS-20-08-481.
Lachiewicz PF, Watters TS. The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg. 2012 Aug;20(8):481–6.
Lachiewicz, Paul F., and Tyler Steven Watters. “The use of dual-mobility components in total hip arthroplasty.J Am Acad Orthop Surg, vol. 20, no. 8, Aug. 2012, pp. 481–86. Pubmed, doi:10.5435/JAAOS-20-08-481.
Lachiewicz PF, Watters TS. The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg. 2012 Aug;20(8):481–486.

Published In

J Am Acad Orthop Surg

DOI

ISSN

1067-151X

Publication Date

August 2012

Volume

20

Issue

8

Start / End Page

481 / 486

Location

United States

Related Subject Headings

  • Reoperation
  • Recurrence
  • Prosthesis Failure
  • Prosthesis Design
  • Polyethylenes
  • Osteoarthritis, Hip
  • Orthopedics
  • Joint Instability
  • Joint Dislocations
  • Humans