Skip to main content
Journal cover image

Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use.

Publication ,  Journal Article
Gurtner, GC; Jones, GE; Neligan, PC; Newman, MI; Phillips, BT; Sacks, JM; Zenn, MR
Published in: Ann Surg Innov Res
January 7, 2013

Inadequate tissue perfusion is a key contributor to early complications following reconstructive procedures. Accurate and reliable intraoperative evaluation of tissue perfusion is critical to reduce complications and improve clinical outcomes. Clinical judgment is the most commonly used method for evaluating blood supply, but when used alone, is not always completely reliable. A variety of other methodologies have been evaluated, including Doppler devices, tissue oximetry, and fluorescein, among others. However, none have achieved widespread acceptance. Recently, intraoperative laser angiography using indocyanine green was introduced to reconstructive surgery. This vascular imaging technology provides real-time assessment of tissue perfusion that correlates with clinical outcomes and can be used to guide surgical decision making. Although this technology has been used for decades in other areas, surgeons may not be aware of its utility for perfusion assessment in reconstructive surgery. A group of experts with extensive experience with intraoperative laser angiography convened to identify key issues in perfusion assessment, review available methodologies, and produce initial recommendations for the use of this technology in reconstructive procedures.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ann Surg Innov Res

DOI

ISSN

1750-1164

Publication Date

January 7, 2013

Volume

7

Issue

1

Start / End Page

1

Location

England
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Gurtner, G. C., Jones, G. E., Neligan, P. C., Newman, M. I., Phillips, B. T., Sacks, J. M., & Zenn, M. R. (2013). Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use. Ann Surg Innov Res, 7(1), 1. https://doi.org/10.1186/1750-1164-7-1
Gurtner, Geoffrey C., Glyn E. Jones, Peter C. Neligan, Martin I. Newman, Brett T. Phillips, Justin M. Sacks, and Michael R. Zenn. “Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use.Ann Surg Innov Res 7, no. 1 (January 7, 2013): 1. https://doi.org/10.1186/1750-1164-7-1.
Gurtner GC, Jones GE, Neligan PC, Newman MI, Phillips BT, Sacks JM, et al. Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use. Ann Surg Innov Res. 2013 Jan 7;7(1):1.
Gurtner, Geoffrey C., et al. “Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use.Ann Surg Innov Res, vol. 7, no. 1, Jan. 2013, p. 1. Pubmed, doi:10.1186/1750-1164-7-1.
Gurtner GC, Jones GE, Neligan PC, Newman MI, Phillips BT, Sacks JM, Zenn MR. Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use. Ann Surg Innov Res. 2013 Jan 7;7(1):1.
Journal cover image

Published In

Ann Surg Innov Res

DOI

ISSN

1750-1164

Publication Date

January 7, 2013

Volume

7

Issue

1

Start / End Page

1

Location

England