Skip to main content

Prone breast tumor imaging using vertical axis-of-rotation (VAOR) SPECT systems: An initial study

Publication ,  Conference
Wang, H; Scarfone, C; Greer, KL; Coleman, RE; Jaszczak, RJ
Published in: IEEE Nuclear Science Symposium & Medical Imaging Conference
December 1, 1996

We propose the use of a single photon emission computed tomography (SPECT) system equipped with multiple cameras revolving around a vertical axis-of-rotation (VAOR) to image tumors in a prone-dependent breast. This innovative breast imaging approach has the advantages of a small attenuation volume between breast lesions and gamma detector as well as a minimal radius-of-rotation compared to conventional (horizontal axis-of-rotation) breast SPECT. Small attenuation volume results in improved detected counts and minimal radius-of-rotation leads to increased collimator resolution. Because of no VAOR SPECT system currently available, we conducted our experiments on a conventional SPECT system using an isolated breast phantom to investigate the proposed VAOR breast SPECT. Our experimental setup simulated a VAOR SPECT study with a prone-dependent breast in the camera's field-of-view. The results of our experiment indicate that VAOR breast SPECT with Trionix LESR parallel hole collimator is capable of detecting a breast lesion with a diameter of 10 mm and a lesion-to-background concentration ratio of 6 to 1. The results also demonstrate that VAOR breast SPECT provides improved lesion visualization over planar scintimammography and conventional breast SPECT.

Duke Scholars

Published In

IEEE Nuclear Science Symposium & Medical Imaging Conference

Publication Date

December 1, 1996

Volume

2

Start / End Page

1387 / 1391
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, H., Scarfone, C., Greer, K. L., Coleman, R. E., & Jaszczak, R. J. (1996). Prone breast tumor imaging using vertical axis-of-rotation (VAOR) SPECT systems: An initial study. In IEEE Nuclear Science Symposium & Medical Imaging Conference (Vol. 2, pp. 1387–1391).
Wang, H., C. Scarfone, K. L. Greer, R. E. Coleman, and R. J. Jaszczak. “Prone breast tumor imaging using vertical axis-of-rotation (VAOR) SPECT systems: An initial study.” In IEEE Nuclear Science Symposium & Medical Imaging Conference, 2:1387–91, 1996.
Wang H, Scarfone C, Greer KL, Coleman RE, Jaszczak RJ. Prone breast tumor imaging using vertical axis-of-rotation (VAOR) SPECT systems: An initial study. In: IEEE Nuclear Science Symposium & Medical Imaging Conference. 1996. p. 1387–91.
Wang, H., et al. “Prone breast tumor imaging using vertical axis-of-rotation (VAOR) SPECT systems: An initial study.” IEEE Nuclear Science Symposium & Medical Imaging Conference, vol. 2, 1996, pp. 1387–91.
Wang H, Scarfone C, Greer KL, Coleman RE, Jaszczak RJ. Prone breast tumor imaging using vertical axis-of-rotation (VAOR) SPECT systems: An initial study. IEEE Nuclear Science Symposium & Medical Imaging Conference. 1996. p. 1387–1391.

Published In

IEEE Nuclear Science Symposium & Medical Imaging Conference

Publication Date

December 1, 1996

Volume

2

Start / End Page

1387 / 1391