MO‐E‐W‐608‐01: Display Evaluation Demonstration Workshop

Publication ,  Conference
Samei, E
Published in: Medical Physics
January 1, 2005

The AAPM TG18 is a new initiative aimed to provide standard guidelines and procedures for acceptance testing and quality control of electronic display devices for medical applications. The recommendations, based on the newly‐designed TG18 test patterns, include detailed visual and quantitative methods and specific acceptance criteria for objective assessment of display quality using the TG18 standard test patterns and specified equipment. The display characteristics considered include luminance, luminance spatial and angular response, resolution, noise, veiling glare, reflection, color uniformity, geometrical distortions, and display artifacts. The goal of this demonstration workshop is to present a tutorial and demonstration on practical aspects of display set up and display performance evaluation based on the TG18 methodology. Representatives from the TG18 committee and from industry will be present to demonstrate and discuss display evaluation issues. Participants: Jeffrey Charette, Barcoview, LLC; Ehsan Samei, Duke University Medical Center; Noriyuki Hashimoto, Eizo Nanao Corporation; Dave Sorensen, Image Systems Corporation; Kenneth Compton, National Display Systems; Adi Abileah, Planar Systems; Hans Roehrig, University of Arizon. © 2005, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2005

Volume

32

Issue

6

Start / End Page

2073

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Samei, E. (2005). MO‐E‐W‐608‐01: Display Evaluation Demonstration Workshop. In Medical Physics (Vol. 32, p. 2073). https://doi.org/10.1118/1.1998315
Samei, E. “MO‐E‐W‐608‐01: Display Evaluation Demonstration Workshop.” In Medical Physics, 32:2073, 2005. https://doi.org/10.1118/1.1998315.
Samei E. MO‐E‐W‐608‐01: Display Evaluation Demonstration Workshop. In: Medical Physics. 2005. p. 2073.
Samei, E. “MO‐E‐W‐608‐01: Display Evaluation Demonstration Workshop.” Medical Physics, vol. 32, no. 6, 2005, p. 2073. Scopus, doi:10.1118/1.1998315.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2005

Volume

32

Issue

6

Start / End Page

2073

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences