SU‐FF‐J‐57: A Phantom Study On the 3‐D Target Localization Accuracy Using CBCT of An On‐Board Imager

Publication ,  Conference
Zhang, L; Yan, H; Yin, F
Published in: Medical Physics
January 1, 2007

Purpose: To evaluate the three‐dimensional target localization accuracy using CBCT of an On‐Board Imager (OBI) system by determining the detection error and residual error associated with image registration and patient repositioning. Method and Materials: An anthropomorphic pelvis phantom was used to simulate a range of shifts in the three translational directions and rotations around each of the three axes. First a simulated shift or rotation was applied. Then a CBCT scan was followed by 3D3D matching between the CBCT 3D volumetric image with the planning CT image. The detected shift vector was compared to the actual shift vector to calculate the detection error. Next the phantom was automatically realigned to the planned position by the OBI system. Subsequently, a second CBCT scan and 3D3D matching was performed to verify the re‐positioning accuracy (residual error). In each of the three translational direction, simulated shifts of 1, 2, 5 and 10 mm were evaluated. In the longitudinal direction large shifts of 20 and 50 mm were evaluated to see whether accuracy was dependant on shift magnitude. Simulated rotations of 1, 3 and 5 degrees around the three axes were also evaluated. Results: On the average, the detection error for translational shifts is 0.4+/−0.3 mm. The average of the corresponding residual error is 0.6+/−0.4 mm. For simulated rotations the average detection error is 0.2+/−0.1 degrees. The average of the corresponding residual error is 0.4+/−0.5 mm. Conclusion: The results indicate that CBCT is capable of detecting target shifts and patient rotation to within 1 mm and 0.5 degree respectively. The shifted target could be realigned to the planned isocenter to within 1mm accuracy when correcting for translational shifts and within 1.8 mm when correcting for rotations. This study is partially supported by a Varian research grant. © 2007, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2007

Volume

34

Issue

6

Start / End Page

2381

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, L., Yan, H., & Yin, F. (2007). SU‐FF‐J‐57: A Phantom Study On the 3‐D Target Localization Accuracy Using CBCT of An On‐Board Imager. In Medical Physics (Vol. 34, p. 2381). https://doi.org/10.1118/1.2760562
Zhang, L., H. Yan, and F. Yin. “SU‐FF‐J‐57: A Phantom Study On the 3‐D Target Localization Accuracy Using CBCT of An On‐Board Imager.” In Medical Physics, 34:2381, 2007. https://doi.org/10.1118/1.2760562.
Zhang, L., et al. “SU‐FF‐J‐57: A Phantom Study On the 3‐D Target Localization Accuracy Using CBCT of An On‐Board Imager.” Medical Physics, vol. 34, no. 6, 2007, p. 2381. Scopus, doi:10.1118/1.2760562.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2007

Volume

34

Issue

6

Start / End Page

2381

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences