Skip to main content
Journal cover image

Effect of radial versus femoral access on radiation dose and the importance of procedural volume: a substudy of the multicenter randomized RIVAL trial.

Publication ,  Journal Article
Jolly, SS; Cairns, J; Niemela, K; Steg, PG; Natarajan, MK; Cheema, AN; Rao, SV; Cantor, WJ; Džavík, V; Budaj, A; Sheth, T; Valentin, V ...
Published in: JACC Cardiovasc Interv
March 2013

OBJECTIVES: The authors sought to compare the radiation dose between radial and femoral access. BACKGROUND: Small trials have shown an increase in the radiation dose with radial compared with femoral access, but many were performed during the operators' learning curve of radial access. METHODS: Patients were randomized to radial or femoral access, as a part of the RIVAL (RadIal Vs. femorAL) trial (N = 7,021). Fluoroscopy time was prospectively collected in 5740 patients and radiation dose quantified as air kerma in 1,445 patients and dose-area product (DAP) in 2,255 patients. RESULTS: Median fluoroscopy time was higher with radial versus femoral access (9.3 vs. 8.0 min, p < 0.001). Median air kerma was nominally higher with radial versus femoral access (1,046 vs. 930 mGy, respectively, p = 0.051). Median DAP was not different between radial and femoral access (52.8 Gy-cm(2) vs. 51.2 Gy·cm(2), p = 0.83). When results are stratified according to procedural volume, air kerma was increased only in the lowest tertile of radial volume centers (low 1,425 vs. 1,045 mGy, p = 0.002; middle 987 vs. 958 mGy, p = 0.597; high 652 vs. 621 mGy, p = 0.403, interaction p = 0.026). Multivariable regression showed procedural volume was the greatest independent predictor of lower air kerma dose (ratio of geometric means 0.55; 95% confidence interval 0.49 to 0.61 for highest-volume radial centers). CONCLUSIONS: Radiation dose as measured by air kerma was nominally higher with radial versus femoral access, but differences were present only in lower-volume centers and operators. High-volume centers have the lowest radiation dose irrespective of which access site approach that they use. (A Trial of Trans-radial Versus Trans-femoral Percutaneous Coronary Intervention (PCI) Access Site Approach in Patients With Unstable Angina or Myocardial Infarction Managed With an Invasive Strategy [RIVAL]; NCT01014273).

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

JACC Cardiovasc Interv

DOI

EISSN

1876-7605

Publication Date

March 2013

Volume

6

Issue

3

Start / End Page

258 / 266

Location

United States

Related Subject Headings

  • Time Factors
  • Radiography, Interventional
  • Radiation Monitoring
  • Radiation Dosage
  • Radial Artery
  • Prospective Studies
  • Percutaneous Coronary Intervention
  • Myocardial Infarction
  • Multivariate Analysis
  • Middle Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Jolly, S. S., Cairns, J., Niemela, K., Steg, P. G., Natarajan, M. K., Cheema, A. N., … RIVAL Investigators, . (2013). Effect of radial versus femoral access on radiation dose and the importance of procedural volume: a substudy of the multicenter randomized RIVAL trial. JACC Cardiovasc Interv, 6(3), 258–266. https://doi.org/10.1016/j.jcin.2012.10.016
Jolly, Sanjit S., John Cairns, Kari Niemela, Philippe Gabriel Steg, Madhu K. Natarajan, Asim N. Cheema, Sunil V. Rao, et al. “Effect of radial versus femoral access on radiation dose and the importance of procedural volume: a substudy of the multicenter randomized RIVAL trial.JACC Cardiovasc Interv 6, no. 3 (March 2013): 258–66. https://doi.org/10.1016/j.jcin.2012.10.016.
Jolly SS, Cairns J, Niemela K, Steg PG, Natarajan MK, Cheema AN, et al. Effect of radial versus femoral access on radiation dose and the importance of procedural volume: a substudy of the multicenter randomized RIVAL trial. JACC Cardiovasc Interv. 2013 Mar;6(3):258–66.
Jolly, Sanjit S., et al. “Effect of radial versus femoral access on radiation dose and the importance of procedural volume: a substudy of the multicenter randomized RIVAL trial.JACC Cardiovasc Interv, vol. 6, no. 3, Mar. 2013, pp. 258–66. Pubmed, doi:10.1016/j.jcin.2012.10.016.
Jolly SS, Cairns J, Niemela K, Steg PG, Natarajan MK, Cheema AN, Rao SV, Cantor WJ, Džavík V, Budaj A, Sheth T, Valentin V, Fung A, Widimsky P, Ferrari E, Gao P, Jedrzejowski B, Mehta SR, RIVAL Investigators. Effect of radial versus femoral access on radiation dose and the importance of procedural volume: a substudy of the multicenter randomized RIVAL trial. JACC Cardiovasc Interv. 2013 Mar;6(3):258–266.
Journal cover image

Published In

JACC Cardiovasc Interv

DOI

EISSN

1876-7605

Publication Date

March 2013

Volume

6

Issue

3

Start / End Page

258 / 266

Location

United States

Related Subject Headings

  • Time Factors
  • Radiography, Interventional
  • Radiation Monitoring
  • Radiation Dosage
  • Radial Artery
  • Prospective Studies
  • Percutaneous Coronary Intervention
  • Myocardial Infarction
  • Multivariate Analysis
  • Middle Aged