Skip to main content
Journal cover image

Intensified Charge Coupled Device-Based Fiber-Optic Monitor for Rapid Remote Surface-Enhanced Raman Scattering Sensing

Publication ,  Journal Article
Alarie, JP; Stokes, DL; Sutherland, WS; Edwards, AC; Vo-Dinh, T
Published in: Applied Spectroscopy
November 1, 1992

This paper describes the development of an intensified charge coupled device (ICCD)-based fiber-optic monitor for remote Raman and surface-enhanced Raman (SERS) sensing. Both Raman and SERS data were obtained with the use of a fiber-optic probe design incorporating 20-m optical fibers carrying the Raman signal. Spectra were obtained in 5 milliseconds for Raman and 9 ms for SERS. The proposed system could be used for a highly sensitive portable Raman system for rapid and remote chemical sensing.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Applied Spectroscopy

DOI

EISSN

1943-3530

ISSN

0003-7028

Publication Date

November 1, 1992

Volume

46

Issue

11

Start / End Page

1608 / 1612

Related Subject Headings

  • Analytical Chemistry
  • 0913 Mechanical Engineering
  • 0306 Physical Chemistry (incl. Structural)
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Alarie, J. P., Stokes, D. L., Sutherland, W. S., Edwards, A. C., & Vo-Dinh, T. (1992). Intensified Charge Coupled Device-Based Fiber-Optic Monitor for Rapid Remote Surface-Enhanced Raman Scattering Sensing. Applied Spectroscopy, 46(11), 1608–1612. https://doi.org/10.1366/0003702924926736
Alarie, J. P., D. L. Stokes, W. S. Sutherland, A. C. Edwards, and T. Vo-Dinh. “Intensified Charge Coupled Device-Based Fiber-Optic Monitor for Rapid Remote Surface-Enhanced Raman Scattering Sensing.” Applied Spectroscopy 46, no. 11 (November 1, 1992): 1608–12. https://doi.org/10.1366/0003702924926736.
Alarie JP, Stokes DL, Sutherland WS, Edwards AC, Vo-Dinh T. Intensified Charge Coupled Device-Based Fiber-Optic Monitor for Rapid Remote Surface-Enhanced Raman Scattering Sensing. Applied Spectroscopy. 1992 Nov 1;46(11):1608–12.
Alarie, J. P., et al. “Intensified Charge Coupled Device-Based Fiber-Optic Monitor for Rapid Remote Surface-Enhanced Raman Scattering Sensing.” Applied Spectroscopy, vol. 46, no. 11, Nov. 1992, pp. 1608–12. Scopus, doi:10.1366/0003702924926736.
Alarie JP, Stokes DL, Sutherland WS, Edwards AC, Vo-Dinh T. Intensified Charge Coupled Device-Based Fiber-Optic Monitor for Rapid Remote Surface-Enhanced Raman Scattering Sensing. Applied Spectroscopy. 1992 Nov 1;46(11):1608–1612.
Journal cover image

Published In

Applied Spectroscopy

DOI

EISSN

1943-3530

ISSN

0003-7028

Publication Date

November 1, 1992

Volume

46

Issue

11

Start / End Page

1608 / 1612

Related Subject Headings

  • Analytical Chemistry
  • 0913 Mechanical Engineering
  • 0306 Physical Chemistry (incl. Structural)
  • 0301 Analytical Chemistry