Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel
Journal cover image

Oversampled triangulation of AWARE-10 monocentric ball lens using an auto-stigmatic microscope

Publication ,  Journal Article
Son, HS; Marks, DL; Brady, DJ; Kim, J
Published in: Optics Express
2013

In our development of multiscale, gigapixel camera architectures, there is a need for an accurate three-dimensional position alignment of large monocentric lenses relative to hemispherical dome structures. In this work we describe a method for estimating the position of the objective lens in our AWARE-10 four-gigapixel camera using the retro-reflected signal of a custom-designed auto-stigmatic microscope. We show that although the physical constraints of the system limit the numerical aperture of the microscope probe beam to around 0.016, which results in poor sensitivity in the axial direction, the lateral sensitivity is more than sufficient to verify that the position of the objective is within optical tolerances. © 2013 Optical Society of America.

Duke Scholars

Published In

Optics Express

DOI

ISSN

1094-4087

Publication Date

2013

Volume

21

Issue

19

Start / End Page

22206 / 22214

Related Subject Headings

  • Signal Processing, Computer-Assisted
  • Optics
  • Microscopy
  • Lenses
  • Image Enhancement
  • Equipment Failure Analysis
  • Equipment Design
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Son, H. S., Marks, D. L., Brady, D. J., & Kim, J. (2013). Oversampled triangulation of AWARE-10 monocentric ball lens using an auto-stigmatic microscope. Optics Express, 21(19), 22206–22214. https://doi.org/10.1364/OE.21.022206
Son, H. S., D. L. Marks, D. J. Brady, and J. Kim. “Oversampled triangulation of AWARE-10 monocentric ball lens using an auto-stigmatic microscope.” Optics Express 21, no. 19 (2013): 22206–14. https://doi.org/10.1364/OE.21.022206.
Son HS, Marks DL, Brady DJ, Kim J. Oversampled triangulation of AWARE-10 monocentric ball lens using an auto-stigmatic microscope. Optics Express. 2013;21(19):22206–14.
Son, H. S., et al. “Oversampled triangulation of AWARE-10 monocentric ball lens using an auto-stigmatic microscope.” Optics Express, vol. 21, no. 19, 2013, pp. 22206–14. Scival, doi:10.1364/OE.21.022206.
Son HS, Marks DL, Brady DJ, Kim J. Oversampled triangulation of AWARE-10 monocentric ball lens using an auto-stigmatic microscope. Optics Express. 2013;21(19):22206–22214.
Journal cover image

Published In

Optics Express

DOI

ISSN

1094-4087

Publication Date

2013

Volume

21

Issue

19

Start / End Page

22206 / 22214

Related Subject Headings

  • Signal Processing, Computer-Assisted
  • Optics
  • Microscopy
  • Lenses
  • Image Enhancement
  • Equipment Failure Analysis
  • Equipment Design
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware