A limitation of fan beam transmission imaging using a 40 cm field-of-view scintillation camera is the data truncation that occurs when imaging medium to large-sized patients. With filtered backprojection, truncation may cause bright rings in the reconstructed image. The primary objective of this study is to evaluate a method to extrapolate the truncated transmission data under clinically relevant count density conditions. The method involves obtaining the patient contour by processing the scatter and photopeak emission data, filling the contour with the attenuation coefficient for soft tissue, reprojecting the contour image, and finally, extrapolating the truncated projection set with the contour projections. A long focal length (114cm) fan beam collimalor is used on one head of a triple camera SPECT system to acquire transmission data. The two remaining detectors are equipped with low energy, ultra high resolution parallel hole collimators. A large thorax phantom (38 cm x 26 cm) and patient data are used to evaluate the method. For SPECT image reconstruction, non-uniform attenuation correction is performed with a truncated attenuation map, an extrapolated attenuation map and the untruncated attenuation map. The SPECT results indicate that image uniformity changes very little using any of the three different attenuation maps when a long focal length fan beam collimator is used for transmission data acquisition. Truncation artifacts that are apparent in the transmission image can be substantially reduced for objects up to 40 cm wide. © 1996 IEEE.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

December 1, 1996

Volume

43

Issue

4 PART 1

Start / End Page

2255 / 2262

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Jaszczak, R. J., Gilland, D. R., McCormick, J. W., Scarfone, C., & Edward Coleman, R. (1996). The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac spect. IEEE Transactions on Nuclear Science, 43(4 PART 1), 2255–2262. https://doi.org/10.1109/23.531890
Jaszczak, R. J., D. R. Gilland, J. W. McCormick, C. Scarfone, and R. Edward Coleman. “The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac spect.” IEEE Transactions on Nuclear Science 43, no. 4 PART 1 (December 1, 1996): 2255–62. https://doi.org/10.1109/23.531890.
Jaszczak RJ, Gilland DR, McCormick JW, Scarfone C, Edward Coleman R. The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac spect. IEEE Transactions on Nuclear Science. 1996 Dec 1;43(4 PART 1):2255–62.
Jaszczak, R. J., et al. “The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac spect.” IEEE Transactions on Nuclear Science, vol. 43, no. 4 PART 1, Dec. 1996, pp. 2255–62. Scopus, doi:10.1109/23.531890.
Jaszczak RJ, Gilland DR, McCormick JW, Scarfone C, Edward Coleman R. The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac spect. IEEE Transactions on Nuclear Science. 1996 Dec 1;43(4 PART 1):2255–2262.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

December 1, 1996

Volume

43

Issue

4 PART 1

Start / End Page

2255 / 2262

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics