Journal articleInvest Radiol · August 2012
Featured Publication
OBJECTIVE: The aim of this study was to compare the image quality of abdominal computed tomography scans in an anthropomorphic phantom acquired at different radiation dose levels where each raw data set is reconstructed with both a standard convolution fil ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · April 2012
Featured Publication
OBJECTIVE: The purpose of our study was to investigate whether virtual unenhanced adrenal nodule attenuation values can replace true noncontrast attenuation values. MATERIALS AND METHODS: Twenty-three incidentally discovered adrenal nodules (19 adenomas an ...
Full textLink to itemCite
Journal articleEur Radiol · January 2012
Featured Publication
OBJECTIVE: To compare the sensitivity, specificity, and diagnostic accuracy of fat-only datasets reconstructed using a two-point Dixon technique, with corresponding opposed-phase (OP) and in-phase (IP) datasets for characterization of adrenal lesions at 3 ...
Full textLink to itemCite
Journal articleRadiology · August 2011
Featured Publication
PURPOSE: To assess the diagnostic accuracy, image quality, and radiation dose of an iterative reconstruction algorithm compared with a filtered back projection (FBP) algorithm for abdominal computed tomography (CT) at different tube voltages. MATERIALS AND ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · June 2011
Featured Publication
OBJECTIVE: The purpose of this article is to assess the impact of large patient size on the detection of hypovascular liver tumors with MDCT and the effect of a noise filter on image quality and lesion detection in obese patients. MATERIALS AND METHODS: A ...
Full textLink to itemCite
Journal articleAbdom Imaging · December 2010
Featured Publication
BACKGROUND: To prospectively investigate the diagnostic accuracy of a 64-section multi-detector row computed tomography (CT) for the detection of peritoneal metastases, with the use of surgery and histopathological findings as the reference standard. METHO ...
Full textLink to itemCite
Journal articleUltraschall Med · October 2010
Featured Publication
PURPOSE: To compare ultrasound (US), low-mechanical index contrast enhanced US (CEUS) and multidetector-CT (MDCT) for the detection of hepatic metastases from colorectal cancer. METHODS AND MATERIALS: From January to June 2006, 110 patients (65 males, 45 f ...
Full textLink to itemCite
Journal articleRadiology · September 2010
Featured Publication
PURPOSE: To prospectively compare gadoxetate disodium-enhanced magnetic resonance (MR) imaging with multiphasic 64-section multidetector computed tomography (CT) in the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis. MATERIALS AND M ...
Full textLink to itemCite
Journal articleRadiology · August 2010
Featured Publication
PURPOSE: To intraindividually compare a low-tube-voltage (80 kVp), high-tube-current (675 mA) computed tomographic (CT) technique with a high-tube-voltage (140 kVp) CT protocol for the detection of pancreatic tumors, image quality, and radiation dose durin ...
Full textLink to itemCite
Journal articleRadiol Med · August 2010
Featured Publication
PURPOSE: The aim of this study was to assess the accuracy of translucency rendering (TR) in computed tomographic (CT) colonography without cathartic preparation using primary 3D reading. MATERIALS AND METHODS: From 350 patients with 482 endoscopically veri ...
Full textLink to itemCite
Journal articleRadiology · August 2010
Featured Publication
PURPOSE: To assess the effect of beam hardening on arterial enhancement in thoracoabdominal computed tomographic (CT) angiography in various body sizes in a phantom and in a clinical study. MATERIALS AND METHODS: An abdominal aortic phantom was placed in t ...
Full textLink to itemCite
Journal articleTop Magn Reson Imaging · June 2010
Featured Publication
The gain in signal-to-noise ratio at 3 T magnetic resonance (MR) imaging produces many benefits for abdominal imaging applications, including the capability to reduce acquisition times and/or improve spatial resolution for a variety of pulse sequences, the ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · June 2010
Featured Publication
OBJECTIVE: The purpose of this study was to determine whether use of dual-energy technique can improve the diagnostic performance of CT in the differential diagnosis of adrenal adenomas and metastatic lesions. SUBJECTS AND METHODS: Thirty-one adrenal nodul ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · April 2010
Featured Publication
OBJECTIVE: The purpose of our study was to evaluate whether two-point Dixon MRI using a 2D decomposition technique facilitates metabolite differentiation between lipids and iron in standardized in vitro liver phantoms with in vivo patient validation and al ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · February 2010
Featured Publication
OBJECTIVE: The purposes of this study were to retrospectively investigate the effectiveness and safety of CT-guided percutaneous drainage in the treatment of patients with acute appendicitis complicated by perforation and to identify CT findings and proced ...
Full textLink to itemCite
Journal articleRadiographics · 2010
Featured Publication
Dual-energy CT provides information about how substances behave at different energies, the ability to generate virtual unenhanced datasets, and improved detection of iodine-containing substances on low-energy images. Knowing how a substance behaves at two ...
Full textLink to itemCite
Journal articleRadiology · January 2010
Featured Publication
PURPOSE: To investigate whether an adaptive statistical iterative reconstruction (ASIR) algorithm improves the image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal computed tomography (CT) during the late hepatic a ...
Full textLink to itemCite
Journal articleRadiology · January 2010
Featured Publication
PURPOSE: To retrospectively compare a two-dimensional (2D) and a three-dimensional (3D) technique for in-phase (IP) and opposed-phase (OP) single-breath-hold 3-T magnetic resonance (MR) imaging in the characterization of adrenal lesions, with histopatholog ...
Full textLink to itemCite
Journal articleJ Comput Assist Tomogr · 2010
Featured Publication
We report a case of an endoscopically confirmed biliary leak of the common hepatic duct after laparoscopic cholecystectomy that was prospectively diagnosed on gadoxetate disodium-enhanced magnetic resonance cholangiography. Whereas dynamic contrast-enhance ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · December 2009
Featured Publication
OBJECTIVE: The purpose of our study was to evaluate the effect of varying volumes and rates of contrast material, use of a saline chaser, and cardiac output on aortic enhancement characteristics in MDCT angiography (MDCTA) using a physiologic phantom. MATE ...
Full textLink to itemCite
Journal articleAcad Radiol · November 2009
Featured Publication
RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT ...
Full textLink to itemCite
Journal articleSemin Ultrasound CT MR · October 2009
Featured Publication
This article reviews focal liver lesions hyperintense on T1-weighted magnetic resonance (MR) images and describes the underlying etiologies associated with their T1 signal intensity. Although focal liver lesions are commonly detected because of their iso- ...
Full textLink to itemCite
Journal articleRadiology · June 2009
Featured Publication
PURPOSE: To intraindividually compare a low tube voltage (80 kVp), high tube current computed tomographic (CT) technique with a standard CT protocol (140 kVp) in terms of image quality, radiation dose, and detection of malignant hypervascular liver tumors ...
Full textLink to itemCite
Journal articleClin Gastroenterol Hepatol · June 2009
Featured Publication
Focal liver lesions are common in the general population. Radiology (imaging) plays a pivotal role for the diagnosis, staging, treatment planning, and follow-up of focal liver lesions. To maximize lesion detection and characterization, imaging needs to be ...
Full textLink to itemCite
Journal articleRadiology · April 2009
Featured Publication
PURPOSE: To prospectively investigate whether combined interpretation of dynamic and hepatobiliary phase magnetic resonance (MR) images can improve the accuracy of gadobenate dimeglumine-enhanced MR imaging in the detection of hepatocellular carcinoma (HCC ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · January 2009
Featured Publication
OBJECTIVE: The purpose of our study was to prospectively assess the added value of isotropic coronal reformations of the liver when using 64-MDCT for the detection of hepatocellular carcinoma (HCC). SUBJECTS AND METHODS: Seventy-one consecutive patients (6 ...
Full textLink to itemCite
Journal articleJ Magn Reson Imaging · September 2008
Featured Publication
We report a case of histologically proven primary leiomyoma of the liver that was evaluated with multiphasic 64-section computed tomography (CT) and gadobenate dimeglumine-enhanced magnetic resonance (MR) imaging. This lesion showed vivid enhancement durin ...
Full textLink to itemCite
Journal articleClin Radiol · May 2008
Featured Publication
Focal nodular hyperplasia is a benign hypervascular hepatic tumour, frequently detected in asymptomatic patients undergoing imaging studies for unrelated reasons. Magnetic resonance imaging (MRI) generally allows a confident differential diagnosis with oth ...
Full textLink to itemCite
Journal articleJ Magn Reson Imaging · April 2007
Featured Publication
PURPOSE: To intraindividually compare the enhancement pattern of focal nodular hyperplasia (FNH) after dynamic administration of two bolus-injectable liver-specific MR contrast agents, ferucarbotran and gadobenate dimeglumine. MATERIALS AND METHODS: A tota ...
Full textLink to itemCite
Journal articleRadiology · December 2005
Featured Publication
PURPOSE: To prospectively evaluate the diagnostic accuracy of low-radiation-dose computed tomographic (CT) colonography for detection of colorectal polyps by using two sequential colonoscopies, with the second colonoscopy as the reference standard. MATERIA ...
Full textLink to itemCite
Journal articleRadiographics · 2005
Featured Publication
Fibropolycystic liver disease encompasses a spectrum of related lesions of the liver and biliary tract that are caused by abnormal embryologic development of the ductal plates. These lesions (congenital hepatic fibrosis, biliary hamartomas, autosomal domin ...
Full textLink to itemCite